The Vanguard CT-7500 S2 Circuit Breaker Analyzer is an easy to use, stand alone or computer-controlled, microprocessor driven EHV circuit breaker analyzer. It can operate either in Time Travel analyzer mode or in “on-line” timing mode. In Time -Travel mode, the Vanguard CT-7500 S2 can fully analyze a circuit breaker’s performance by testing the contact time, stroke, veloci ty, over travel, and contact wipe. Contact motion analysis can be performed for all circuit breaker operations (Open, Close, Open – Close, Close – Open, and Open – Close – Open). The timing window of the Vanguard CT-7500 S2 is selectable between 1 second, 10 second, or 20 second periods. The 10 second and 20 second timing windows are ideal for timing long duration events such as circuit switcher contact testing.

Features

  • On-Line Timing
  • Capture First Trip Time
  • Full Breaker Tabulated & Graphic Data Printout
  • Built-in Thermal Printer
  • Initiate Breaker Operation
  • Digital Travel Transducer; No Setup or Calibration Required
  • Support resistor type transducer
  • Detect Main Contact and Insertion Resistor Contact on the Same Input Channel
  • Store 100 records and 99 test plans
  • USB and RS-232C computer interfaces
  • Diagnostic Capabilities

Available Models

  • CT-7500-3 S2 (3 contact channels)
  • CT-7500-6 S2 (6 contact channels)
  • CT-7500-12 S2 (12 contact channels)
  • Physical Specifications: 16”W x 11”H x 14”D (40.6 cm x 29.9 cm x 35.6 cm); Weight: less than 25 lbs (11.3 kg)
  • Input Power: 100 – 120 Vac or 200 – 240 Vac (selectable), 50/60Hz
  • Dry-Contact Inputs: 3, 6 or 12 dry-input channels (depending on model). Each channel detects main and insertion-resistor contacts
  • Timing Windows: 1-second, 10-seconds, or 20-seconds
  • Timing Resolutions: ±50 micro-seconds @ 1-second duration, ±500 micro-seconds @ 10-second duration, ±1.0 milli-seconds @ 20-second duration
  • Timing Accuracy: 0.05% of reading ±0.05 ms @ 1-second duration
  • Dry-Contact Channel Protection: All contact inputs are grounded until test; input channels are protected against static discharge
  • Dry-Contact Detection Range: Closed: less than 20 ohms; Open: greater than 5,000 ohms
  • Resistor Detection Range: 50 – 5,000 ohms
  • Ct Current Sensor: One, non-contact, 0 – 100 Amperes
  • Trigger Input Voltage: Open/Close: 30 – 300V, DC or peak AC
  • Voltage Sensing Input Range: V1: analog input; 0 – 255V DC or peak AC; Sensitivity ±1V V2: voltage presence/absence detector input; 30 – 300V DC or peak AC
  • Breaker Operations: Initiate Open, Close, Open – Close, Close – Open, Open – Close – Open
  • Breaker Initiate Capacity: 30A, 250Vac/dc max
  • Initiate Current Reading Range: One, non-contact, Hall-effect sensor, 0 – 20 amp range, dc to 5Khz
  • Digital Travel Transducer Inputs: 3 digital travel transducer channels; Linear range, 0.0 – 60.0 in (±0.01 in); Rotary range: 0 – 360 degrees (±0.36 degrees)
  • Resistor Type Transducer Input: 200 Ohms – 10K Ohms
  • Contact Travel Point Difference: Measures “slow-close” contact-point distances; results can be printed
  • Display: Back-lit LCD Screen (20 characters by 4 lines); viewable in bright sunlight and low-light levels
  • Printer: Built-in 4.5-inch wide thermal printer can print both graphic contact travel waveforms and tabulated test results
  • Internal Test Record Storage: Stores up to 150 test records and 99 test plans
  • Computer Interfaces: One RS-232C port, One USB port
  • Pc Software: Windows® XP/Vista-based Breaker-Analysis software is included with purchase price
  • Safety: Designed to meet UL 6101A-1 and CAN/CSA C22.2 No 1010.1-92 standards
  • Environment: Operating: -10°C to 50°C (+15°F to +122°F); Storage: -30°C to70°C (-22°F to +158°F)
Description

The Vanguard CT-7500 S2 Circuit Breaker Analyzer is an easy to use, stand alone or computer-controlled, microprocessor driven EHV circuit breaker analyzer. It can operate either in Time Travel analyzer mode or in “on-line” timing mode. In Time -Travel mode, the Vanguard CT-7500 S2 can fully analyze a circuit breaker’s performance by testing the contact time, stroke, veloci ty, over travel, and contact wipe. Contact motion analysis can be performed for all circuit breaker operations (Open, Close, Open – Close, Close – Open, and Open – Close – Open). The timing window of the Vanguard CT-7500 S2 is selectable between 1 second, 10 second, or 20 second periods. The 10 second and 20 second timing windows are ideal for timing long duration events such as circuit switcher contact testing.

Features

  • On-Line Timing
  • Capture First Trip Time
  • Full Breaker Tabulated & Graphic Data Printout
  • Built-in Thermal Printer
  • Initiate Breaker Operation
  • Digital Travel Transducer; No Setup or Calibration Required
  • Support resistor type transducer
  • Detect Main Contact and Insertion Resistor Contact on the Same Input Channel
  • Store 100 records and 99 test plans
  • USB and RS-232C computer interfaces
  • Diagnostic Capabilities

Available Models

  • CT-7500-3 S2 (3 contact channels)
  • CT-7500-6 S2 (6 contact channels)
  • CT-7500-12 S2 (12 contact channels)