Close
You have no items in your shopping cart.

EM Test UCS 500N7 Multifunctional Transient Immunity Simulator

Manufacturer part number: UCS-500N7
The EM Test UCS500N7 Multifunctional Transient Immunity Simulator includes everything necessary to conduct fully compliant tests at levels that go far beyond common test requirements. Surge can be tested up to 7.0kV either according to IEC/EN 61000-4-5 or ANSI/IEEE C62.41. The UCS 500N7 offers an integrated Ringwave module (optional) as per ANSI/IEEE C62.41 and IEC/EN 61000-4-12 for ringwave tests on mains supply lines.
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

The EM Test UCS500N7 Multifunctional Transient Immunity Simulator includes everything necessary to conduct fully compliant tests at levels that go far beyond common test requirements.

Surge can be test up to 7.0kV either according to IEC/EN 61000-4-5 or ANSI/IEEE C62.41. The UCS 500N7 offers an integrated Ringwave module (optional) as per ANSI/IEEE C62.41 and IEC/EN 61000-4-12 for ringwave tests on mains supply lines.

The EM Test UCS 500N7 can be operated manually from the front panel or by remote via the built-in USB or GPIB interface. Fail inputs allow to control an ongoing test sequence based on the status of the DUT. Monitoring outputs (BNC) are offered for easy signal measurement and verification. Safety features such as interlock and warning lamp control are available.

Pre-programmed Standard Test routines allow highest user convenience. Still the UCS 500N7 offers the Quick Start test routine where parameters can be changed on-line during the test to evaluate the susceptibility level of an individual DUT, a most appreciated benefit for tests at development stage.

The EM Test UCS500N7 Multifunctional Transient Immunity Simulator is the most versatile tester to cover transient and power fail requirements according to international standards (basic and generic standards) and product/ product family standards with voltage capability of up to 7.0 kV. Apart from the IEC/EN 61000-4-5 standard for surge testing it also complies to ANSI/IEEE C62.41 for surge and ringwave testing.

The UCS 500N7 not only represents the most economic solution for full-compliant immunity tests and CE Marking but goes far beyond. Having a built-in CDN for single phase DUTs it can be extended for testing three-phase DUTs by means of an automatically controlled external coupling network up to 100A.

  • Standards Met: ANSI/IEEE C62.41; IEC 61000-4-11; IEC 61000-4-12; IEC 61000-4-29; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-8; IEC 61000-4-9; EN 61000-6-1; EN 61000-6-2; ITU-T K.XX; UL 1741
  • Application/Test Type: CE Marking - Cover transient and power fail requirements according to international standards for immunity tests
  • Pulse Voltage (Open Circuit): 250 V - 7,000 V ± 10%
  • Impedance: 2 Ohm / 12 Ohm
  • Pulse Current (Short Circuit): Max. 3,500 A ± 10%
  • Coupling: As per IEC 61000-4-5: Line to line with 2 ohm, Line(s) to ground with 12 ohm; As per ANSI/IEEE C62.41: Line to line with 2ohm, Line(s) to ground with 2ohm
  • Repitition Time: 10 ms - 9,999 ms
  • Pulse Repitition: Max. 0.5 Hz (2 s - 999 s)
  • Phase Synchronization: 0° - 360°, resolution 1° (16 - 500Hz)
  • Polarity: positive / negative / alternating
  • Phase Synchronization: 0° - 360°, resolution 1°
  • Coupling: L, N, PE; all combinations
  • Dips, Interrupts & Variations: As per IEC/EN 61000-4-11, IEC/EN 61000-4-29 and IEC/EN 61000-6-1, -6-2
  • Test Duration: 1 - 30,000 or endless, selectable
  • Test Duration: 0:01min - 99:59min
  • Uvar with Step Transformer: 300 V AC
  • Peak Inrush Current Capability: 500 Amps
  • Serial Interface: USB
  • Parallel Interface: IEEE 488, addresses 1 - 30
  • Analog Output: 0 - 10 VDC to control an external transformer
  • CN Interface: 15pin SubD connector to control an external coupling network
  • Fail Inputs: DUT monitoring via Fail1 and Fail2 input (one each)
  • Supply Voltage: 115 / 230 VAC +10%/-15%
  • Power Consumption: Approx. 75 W
  • Frequency: 50/60 Hz
  • Fuses: 2x 2 AT (230 V) or 2x 4 AT (115 V)
  • Housing: 19", 6 HU
  • Weight: Approx. 29 kg
Description

The EM Test UCS500N7 Multifunctional Transient Immunity Simulator includes everything necessary to conduct fully compliant tests at levels that go far beyond common test requirements.

Surge can be test up to 7.0kV either according to IEC/EN 61000-4-5 or ANSI/IEEE C62.41. The UCS 500N7 offers an integrated Ringwave module (optional) as per ANSI/IEEE C62.41 and IEC/EN 61000-4-12 for ringwave tests on mains supply lines.

The EM Test UCS 500N7 can be operated manually from the front panel or by remote via the built-in USB or GPIB interface. Fail inputs allow to control an ongoing test sequence based on the status of the DUT. Monitoring outputs (BNC) are offered for easy signal measurement and verification. Safety features such as interlock and warning lamp control are available.

Pre-programmed Standard Test routines allow highest user convenience. Still the UCS 500N7 offers the Quick Start test routine where parameters can be changed on-line during the test to evaluate the susceptibility level of an individual DUT, a most appreciated benefit for tests at development stage.

The EM Test UCS500N7 Multifunctional Transient Immunity Simulator is the most versatile tester to cover transient and power fail requirements according to international standards (basic and generic standards) and product/ product family standards with voltage capability of up to 7.0 kV. Apart from the IEC/EN 61000-4-5 standard for surge testing it also complies to ANSI/IEEE C62.41 for surge and ringwave testing.

The UCS 500N7 not only represents the most economic solution for full-compliant immunity tests and CE Marking but goes far beyond. Having a built-in CDN for single phase DUTs it can be extended for testing three-phase DUTs by means of an automatically controlled external coupling network up to 100A.