Close
You have no items in your shopping cart.

Teseq GTEM 250 Test Cell

Manufacturer part number: GTEM-250
Test Cell complete with door and fan. 50W max. RF input. Outer dimensions 1.25x0.65x0.45m. Door size 0.20x0.13m. Max. EUT size 0.20x0.20x0.15m.
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

Teseq GTEM 250 Test Cell

A GTEM (Gigahertz Transverse Electro Magnetic) cell is a test site for efficiently performing both radiated immunity and emissions testing in a single, controllable and shielded environment. Compared to other test sites, GTEM testing is faster with high accuracy and excellent reproducibility. In principle, the GTEM cell is a coaxial line expanding pyramidally and having an impedance of 50 Ω. At its end, the line is terminated by a combination of termination resistors and RF absorbers designed and constructed to match the above mentioned impedance. The GTEM 250 has a maximum septum height of 250 mm and is suitable for emissions and immunity testing.

Features

  • Emissions and immunity testing in a single, shielded environment
  • Meets basic standard: IEC/EN 61000-4-20
  • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
  • Meets standards for immunity testing: EN 60118-13
  • Ideal for design qualification and pre-certification
  • Max. septum height: 250 mm
  • Septum height at marker position: 217 mm
  • Dimension (LxWxH): 1.25 x 0.65 x 0.45 m
  • Weight: 45 kg
  • CISPR 14-1
  • EN 61000-6-3
  • EN 61000-6-4
  • IEC 61000-4-20
  • ISO 11452-3
  • SAE J1113-24
Description

Teseq GTEM 250 Test Cell

A GTEM (Gigahertz Transverse Electro Magnetic) cell is a test site for efficiently performing both radiated immunity and emissions testing in a single, controllable and shielded environment. Compared to other test sites, GTEM testing is faster with high accuracy and excellent reproducibility. In principle, the GTEM cell is a coaxial line expanding pyramidally and having an impedance of 50 Ω. At its end, the line is terminated by a combination of termination resistors and RF absorbers designed and constructed to match the above mentioned impedance. The GTEM 250 has a maximum septum height of 250 mm and is suitable for emissions and immunity testing.

Features

  • Emissions and immunity testing in a single, shielded environment
  • Meets basic standard: IEC/EN 61000-4-20
  • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
  • Meets standards for immunity testing: EN 60118-13
  • Ideal for design qualification and pre-certification
Product tags