Close
You have no items in your shopping cart.

Teseq CDN 3083 Manual Surge Coupling/Decoupling Network

Manufacturer part number: CDN-3083-S100
Surge 620 Volt, 100-200 Amp Manual Coupler
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

Key Features and Functions

The Teseq CDN 3083 manual coupling/decoupling network fulfills the requirements specified in the surge standard IEC / EN 61000-4-5: 2014. Designed for convenient use in a wide variety of test environments, the CDN 3083 can be placed on the floor or table-top or may be mounted on a wall in an EMC laboratory or development workshop. Since high current couplers must often be taken to remote test sites, the Teseq CDN 3083 can be easily disassembled into handy modules for moving.

The unit is fitted with wheels and brakes for use on ramps or uneven surfaces. Currents over 100 Amps per phase are allowed for short test periods (CDN 3083-S100). The CDN 3083 is designed to withstand frequently encountered inrush currents and, in extreme cases, can be overstressed until the internal environment has reached the maximum temperature.

Rugged connection terminals, as well as a solid housing are featured to ensure safe, reliable operation. The CDN 3083 is tested for safety in compliance with IEC 61010. Surge levels up to 8 kV / 4 kA with 1.2 / 50 μs combination wave can be coupled by the CDN 3083.

EUT supply voltages of up to 620 V rms or 620 VDC at 100 A are supported. The CDN 3083 is designed for simple and safe manual operation. All symmetrical and asymmetrical coupling modes of IEC / EN 61000-4-5 and ANSI C62.41 are supported by the CDN 3083.

Voltage Rating620 VAC RMS L-to-L (max. 440 V for NSG 3040 and Modula); 620 VAC RMS L-to-PE (max. 440 V for NSG 3040 and Modula); 620 VDC
Standards MetIEC / EN 61000-4-5:2005, ANSI C62.45 standard, in IEC / EN 61000-4-12:2006 and ANSI C62.41
Mains & EUT ConnectionsFischer 105 series; Screw terminals, rated for 230 A
Current Rating100 Amp or 200 Amp continous depending on model
Application/Test TypeManual Surge Testing for EUT up to 100Amps, 620 VAC; Three phase (5 wire); Two phase (4 wire); Single phase (3 wire)
RF Input VoltageMax. 8 kV / 4 kA
Dimensions850 x 520 x 345 mm
Weight80 kg (176 LB's)
Description

Key Features and Functions

The Teseq CDN 3083 manual coupling/decoupling network fulfills the requirements specified in the surge standard IEC / EN 61000-4-5: 2014. Designed for convenient use in a wide variety of test environments, the CDN 3083 can be placed on the floor or table-top or may be mounted on a wall in an EMC laboratory or development workshop. Since high current couplers must often be taken to remote test sites, the Teseq CDN 3083 can be easily disassembled into handy modules for moving.

The unit is fitted with wheels and brakes for use on ramps or uneven surfaces. Currents over 100 Amps per phase are allowed for short test periods (CDN 3083-S100). The CDN 3083 is designed to withstand frequently encountered inrush currents and, in extreme cases, can be overstressed until the internal environment has reached the maximum temperature.

Rugged connection terminals, as well as a solid housing are featured to ensure safe, reliable operation. The CDN 3083 is tested for safety in compliance with IEC 61010. Surge levels up to 8 kV / 4 kA with 1.2 / 50 μs combination wave can be coupled by the CDN 3083.

EUT supply voltages of up to 620 V rms or 620 VDC at 100 A are supported. The CDN 3083 is designed for simple and safe manual operation. All symmetrical and asymmetrical coupling modes of IEC / EN 61000-4-5 and ANSI C62.41 are supported by the CDN 3083.