About the Teseq CAS CDNE Calibration Kit for CDNE

The Calibration Kit CAS CDNE is made for function tests and verification measurements on coupling decoupling network for emissions measurements (CDNE). Measuring parameters are common-mode (CM) impedance, (CM) phase angle, voltage division factor, decoupling attenuation and differential-mode (DM) impedance. CDNEs and measurements on CDNEs are defined in CISPR 16-1-2.

The CAS CDNE contains adapters for establishing the 150 Ω to 50 Ω connection, the common-mode, the length correction, the impedance measuring and the differential-mode measurements, including a measuring balun with a balanced output of 100 Ω.

Specifications & Features of Teseq CAS CDNE:

  • Frequency range: (100 kHz) 1 MHz to 300 MHz
  • Impedance ratio (unbalanced / balanced): 50 / 100
  • Insertion loss, typical: 16.2 dB at 30 MHz (back to back; 8.1 dB for single unit)
  • Flatness, typical: < 1 dB at 100 kHz to 300 MHz
  • VSWR, typical
    • 50 Ω port: < 1:1.25 at 1 MHz to 300 MHz (100 kHz < 1:1.5)
    • 100 Ω port: < 1:1.25 at 100 kHz to 300 MHz
  • LCL, typical, 100 Ω port:
    • 90 dB at 100 kHz
    • 80 dB at 10 MHz
    • 55 dB at 100 MHz
  • CMR, typical: 65 dB to 25 dB at 1 MHz to 300 MHz
  • Amplitude balance, typical:
    • < 0.1 dB at 100 kHz to 100 MHz
    • < 0.2 dB at 100 MHz to 300 MHz
  • Phase balance, typical:
    • < 2° at 100 kHz to 100 MHz
    • < 5° at 100 MHz to 300 MHz
  • Max. power: 20 dBm
  • Connector
    • 50 Ω port: BNC female
    • 100 Ω port: 1 mm female (2x 100 Ω port, 1x ground)
  • Dimension (LxWxH): 72 mm x 32 mm x 27 mm
  • Weight: approx. 85 g

Items Included:

Qty.

Item

Description

1

IMA U100

Impedance measuring adapter

1

CAL U100B

50 Ω/150 Ω-adapter

1

SAR M210E-open

CM adapter for CDNE M210, part for setting the delay time

2

SAR M210E

CM adapter for CDNE M210

1

SAR M310E-open

CM adapter for CDNE M310, part for setting the delay time

2

SAR M310E

CM adapter for CDNE M310

1

TRA U0-150

Termination load 0 Ω and 150 Ω

1

MB 300

Measuring balun

1

Support

Provides the set-up position of MB 300

1

Open 1mm

Adapter “open” for 1 mm

1

Short 1mm

Adapter “short” for 1 mm

1

Match 1mm

Adapter “match” for 1 mm

1

AD 1mm/4mm

1 mm/4 mm Adapter

1

A 50-BNC

50 Ω (for termination the RF port of the CDNE)

1

Storage box

Storage box

Description

About the Teseq CAS CDNE Calibration Kit for CDNE

The Calibration Kit CAS CDNE is made for function tests and verification measurements on coupling decoupling network for emissions measurements (CDNE). Measuring parameters are common-mode (CM) impedance, (CM) phase angle, voltage division factor, decoupling attenuation and differential-mode (DM) impedance. CDNEs and measurements on CDNEs are defined in CISPR 16-1-2.

The CAS CDNE contains adapters for establishing the 150 Ω to 50 Ω connection, the common-mode, the length correction, the impedance measuring and the differential-mode measurements, including a measuring balun with a balanced output of 100 Ω.