Sorensen DCS50-40M16 Three Phase Power Supply

Manufacturer part number: DCS50-40M16
190 - 250 VAC
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   1
+ -
$0.00Configurations
X

Available Configurations

190-250VAC THREE PHASE POWER SUPPLY
30009033
$0

The front panel features a 10-turn current control knob with a locking shaft, along with a current monitor (100mv/Amp). The voltage (and current) can be monitored and controlled via the "programming, sense, and monitor connector, J3," located on the back of the unit. See the product manual for details. These units were manufactured in a configuration without front panel meters and no front panel voltage control.

Features:

  • 190-250 Vac single or 3-phase input, 47-63 Hz
  • Ten turn locking potentiometer current control permits high-resolution setting of the output current from zero to the rated output
  • Automatic mode crossover into current or voltage mode
  • Flexible output configuration: multiple units can be connected in parallel or series to provide increased current or voltage
  • High-frequency switching technology allows high power density, providing increased power output in a small, light package
  • Remote sensing to compensate for losses in power leads
  • Preset Over-Voltage Protection (OVP)
  • External TTL, AC or DC shutdown
  • Remote voltage, resistive, current limit, and OVP programming with selectable programming constants
  • Input Power: 
    • Voltage: 200-250VAC single phase, or 190-250VAC three phase
    • Frequency: 47-63Hz 
    • Current draw with 2kW load: 14A RMS with 3 phase input, 20A RMS with single phase
  • Output Power: 
    • 2000 watts maximum, 0 watts minimum 
    • Voltage internally set for a maximum compliance of 53V ± 1VDC 
    • Current adjustable from 0 to 38 amps DC
  • Response Time: 
    • Less than 1 ms recovery to 1% band for 30% step load changes from 70% to 100% or 100% to 70%
  • Drift: 
    • Less than 0.05% over 8 hours in voltage or current mode after a 30 minute warmup period
    • Switching Frequency: Nominal 65kHz (130kHz output ripple)
    • Ripple Voltage: 200mV peak-to-peak, 20mV RMS, 20MHz limited
Description

The front panel features a 10-turn current control knob with a locking shaft, along with a current monitor (100mv/Amp). The voltage (and current) can be monitored and controlled via the "programming, sense, and monitor connector, J3," located on the back of the unit. See the product manual for details. These units were manufactured in a configuration without front panel meters and no front panel voltage control.

Features:

  • 190-250 Vac single or 3-phase input, 47-63 Hz
  • Ten turn locking potentiometer current control permits high-resolution setting of the output current from zero to the rated output
  • Automatic mode crossover into current or voltage mode
  • Flexible output configuration: multiple units can be connected in parallel or series to provide increased current or voltage
  • High-frequency switching technology allows high power density, providing increased power output in a small, light package
  • Remote sensing to compensate for losses in power leads
  • Preset Over-Voltage Protection (OVP)
  • External TTL, AC or DC shutdown
  • Remote voltage, resistive, current limit, and OVP programming with selectable programming constants