The OCS 500N6

The OCS 500N6 includes test capabilities for ringwave up to 6kV (as per EN/IEC 61000-4-12) and the damped oscillatory waves at 100 kHz and 1 MHz up to 3 kV (as per EN/IEC 61000-4-18).The Ringwave is a non-repetitive damped oscillatory transient occurring in low-voltage power, control and signal lines supplied by public and non-public networks. Damped Oscillatory Waves are repetitive transients mainly occurring in power, control and signal cables installed in high voltage and medium voltage stations. The OCS 500N6 can also be used to perform magnetic field tests as required in EN/IEC 61000-4-10 using a magnetic field coil such as the MS 100N.

Features:

  • Standalone test generator
  • Includes Ringwave up to 6 kV
  • Includes Damped Oscillator Waves up to 3 kV
  • Built-in CDN, single phase or three-phase up to 100 A
  • Front panel operation
  • Voltage: (o.c.) 250 V - 6,000 V ± 10 %
  • Rise time: 0.5 us ± 30 %
  • Oscillation frequency: 100 kHz ± 10 %
  • Decaying: Ratio of peak 2 to peak 1: 0.4 - 1.1; Ratio of peak 3 to peak 2: 0.4 - 0.8; Ratio of peak 4 to peak 3: 0.4 - 0.8
  • Source impedance: 12 ohm and 30 ohm ± 20 %
  • Peak current: (s.c.) Max. 500 A @ 12 ohm or Max. 200 A @ 30 ohm internally;
  • Rise time: 0.2 us to 1.0 us
  • Oscillation frequency: 100 kHz ± 10 %
  • Polarity: Positive, negative
  • Repetition rate: 1 / min or faster
Description

The OCS 500N6

The OCS 500N6 includes test capabilities for ringwave up to 6kV (as per EN/IEC 61000-4-12) and the damped oscillatory waves at 100 kHz and 1 MHz up to 3 kV (as per EN/IEC 61000-4-18).The Ringwave is a non-repetitive damped oscillatory transient occurring in low-voltage power, control and signal lines supplied by public and non-public networks. Damped Oscillatory Waves are repetitive transients mainly occurring in power, control and signal cables installed in high voltage and medium voltage stations. The OCS 500N6 can also be used to perform magnetic field tests as required in EN/IEC 61000-4-10 using a magnetic field coil such as the MS 100N.

Features:

  • Standalone test generator
  • Includes Ringwave up to 6 kV
  • Includes Damped Oscillator Waves up to 3 kV
  • Built-in CDN, single phase or three-phase up to 100 A
  • Front panel operation