Narda-STS EB 5091 E-Field Probe, Shaped IEEE

Manufacturer part number: EB5091
Narda-STS EB 5091 Probe: E-Field, shaped IEEE, 3MHz to 50GHz, 0.5 to 600% of IEEE, C95.1-2005 for People in Controlled Environments. For use with NBM-series meters.
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

Narda-STS EB5091 E-Field Probe, Shaped IEEE

Narda Safety Test Solutions EB5091 Probe: E-Field, shaped IEEE, 3MHz to 50GHz, 0.5 to 600% of IEEE, C95.1-2005 for People in Controlled Environments.

The Narda NBM-Series of probes provide Electric or Magnetic and Flat or Shaped response coverage. Detection is performed by diode, thermocouple or compensated diode with thermocouple for the highest accuracy obtainable.

There is an internal eeprom in each probe to identify the probe to the meter and provide all calibration and measurement range data.

These probes contain 6 dipoles, three diode based and three thermocouple based dipoles. The correctly tuned overlap of two dipoles, one acting as a high pass filter the other as a low pass filter, provides a frequency sensitivity that mirrors a particular standard. Testing for compliance to that standard is very easy to perform, as the emitted frequency need not be known.

  • Calibration
  • Calibration certificate
  • Manual
  • All additional standard accessories
  • 300kHz to 50GHz
  • Standard: 0.5 to 600% of IEEE C95.1-2005, Controlled Environment
  • Dynamic Range: 30dB
  • Directivity: Isotropic (non-directional tri-axial)
  • Compatibility: NBM-500 series meters
  • RF Safety
Description

Narda-STS EB5091 E-Field Probe, Shaped IEEE

Narda Safety Test Solutions EB5091 Probe: E-Field, shaped IEEE, 3MHz to 50GHz, 0.5 to 600% of IEEE, C95.1-2005 for People in Controlled Environments.

The Narda NBM-Series of probes provide Electric or Magnetic and Flat or Shaped response coverage. Detection is performed by diode, thermocouple or compensated diode with thermocouple for the highest accuracy obtainable.

There is an internal eeprom in each probe to identify the probe to the meter and provide all calibration and measurement range data.

These probes contain 6 dipoles, three diode based and three thermocouple based dipoles. The correctly tuned overlap of two dipoles, one acting as a high pass filter the other as a low pass filter, provides a frequency sensitivity that mirrors a particular standard. Testing for compliance to that standard is very easy to perform, as the emitted frequency need not be known.