ACV: 0V to 250V (±2%, ± 1V)
DCV: 0V to ±300V (±2%, ±1V)
Resistance: 0 Ω to 1,000 KΩ (±2%, ±1 Ω)
Leakage: 1 MΩ to 999 MΩ (±3%), 150 V open circuit output
Longitudinal Balance: +30 dBrn to +80 dBrn (±2 dBrn)
Super Stress: -10 dBrn to +30 dBrn (±2 dBrn)
Load Coil Detection: 0 coil to 4 coils (±1 coil)
Loop Current: 0 mA to ±100 mA (±2%, ±1 mA)
Power Influence: +40 dBrnC to +100 dBrnC (±2 dBrnC)
Noise (Voice Band): 0 dBrnC to +60 dBrnC (±2 dBrnC)
Loss (Voice Band): -40 dBm to +10 dBm (±1 dBm)
Open Meter:
- 0 m (0 ft) to 900 m (3,000 ft)
- :±2%, ±1.5 m (5ft)
- :900 m (3,000 ft) to 15 km (50,000 ft) (±3%)
Auto Test: 7 user-selectable auto test scripts, 200 pair storage, retest capability, Incremental pair testing program
Caller ID: Yes
ID Tone:
- Frequency: 577.5 Hz (±1%)
- Amplitude: 0 dBm, 600 Ω (±1 dBm)
Wideband Tone Send:
- Frequency: 20 KHz to 9 MHz (±1%)
- Amplitude: 0 dBm, 135 Ω (±1 dBm)
Wideband Tone Receive:
- Frequency: 20 KHz to 33 MHz
- Amplitude: -90 dBm, +2 dBm (±2 dBm)
Wideband Loss:
- Frequency: 20 KHz to 33 MHz
- Amplitude: -90 dBm, +2 dBm (±2 dBm) RFL
- Distance to Fault: 0 – 3.000m (10,000 ft) ±0.5%, ±1m (3 ft)
- Maximum Measurable Fault Resistance: 100 MΩ
- Maximum Locatable Fault Resistance: 2 MΩ
TDR: Dual trace, 12 trace memory storage, Automatic pulse width selection, Pair comparison mode, Split/crosstalk mode, Intermittent fault location,mode, Intermittent fault location
- Closest Range: 0 – 8 m (25 ft)
- Longest Range: 0 – 16.000 m (49,000 ft) (@VOP = 0.7), Zoom mode
Wideband Spectrum analyzer:
- Frequency: 20 KHz to 33 MHz
- Amplitude: -90 dBm to +10 dBm (±2 dBm), -130 dBm/Hz to -30 dBm/Hz (±2 dBm/Hz)
Impulse noise:
- Amplitude: -45 dBm to +10 dBm (±2 dBm)
- Filters: F, G, J, None (30 MHz)
Voiceband Spectrum Analyzer:
- Frequency: 50 Hz to 4,100 Hz
- Amplitude: -64 dBm to 0 dBm (±2 dBm), -76 dBm/Hz to -12 dBm/Hz (±2 dBm/Hz)
Display: High resolution, 1/4 VGA graphics with LED backlight
Batteries: Rechargeable nickel-metal hydride
Battery Life: Approximately 30 hours typical usage