A.H. Systems ICP-621 Current Injection Probe

Manufacturer part number: ICP-621
10 kHz–100 MHz
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

The AH Systems ICP-621 current injection probe is used for specifications that require the injection of large frequency currents into cable bundles and individual wires. It can be used as an injection source as well as a sensitive monitoring probe. The ICP-621 has an input power rating of 100 watts CW for 30 minutes and covers the frequency range of 10 KHz - 100 MHz.

Typical specifications requiring the use of current injection probes are:

  • IEC 61000-4-6
  • Mil-Std 461
  • DO-160
  • EN-50081-1
  • IEC 801-6
  • TR-EOP-000063

AH Systems ICP-621 Features:

  • Broad Frequency Range of 10 KHz to 100 MHz
  • Individually Calibrated (Insertion Loss and Transfer Impedance calibration included)
  • Split Type Clamp-on Design
  • Current injection source as well as a sensitive monitoring probe.
  • Insertion Loss: 8 to 30 dB
  • Max Input Power: 100 Watts
  • Connector: N-type, Female
  • Aperture: 1.5" (38mm)
  • Diameter: 4.25" (108mm)
  • Weight: 4.2 lbs (1.9 kg)
  • Frequency Range: 10 KHz - 100 MHz
  • Insertion Loss: 8 to 30 dB
  • Transfer Impedance: 0 to 22 dBΩ
  • Rated Watts: 100 watts CW
  • Connector: N-Type, female
  • Inner Diameter: 1.5 in. (38 mm)
  • Outer Diameter: 4.25 in. (108 mm)
  • Height: 2.5 in. (64 mm)
  • Weight: 4.2 lbs (1.9 kg)
Description

The AH Systems ICP-621 current injection probe is used for specifications that require the injection of large frequency currents into cable bundles and individual wires. It can be used as an injection source as well as a sensitive monitoring probe. The ICP-621 has an input power rating of 100 watts CW for 30 minutes and covers the frequency range of 10 KHz - 100 MHz.

Typical specifications requiring the use of current injection probes are:

  • IEC 61000-4-6
  • Mil-Std 461
  • DO-160
  • EN-50081-1
  • IEC 801-6
  • TR-EOP-000063

AH Systems ICP-621 Features:

  • Broad Frequency Range of 10 KHz to 100 MHz
  • Individually Calibrated (Insertion Loss and Transfer Impedance calibration included)
  • Split Type Clamp-on Design
  • Current injection source as well as a sensitive monitoring probe.
  • Insertion Loss: 8 to 30 dB
  • Max Input Power: 100 Watts
  • Connector: N-type, Female
  • Aperture: 1.5" (38mm)
  • Diameter: 4.25" (108mm)
  • Weight: 4.2 lbs (1.9 kg)