Narda 27MHz-1GHz HFD-0191: H-Field Probe(For fieldman)

Manufacturer part number: 2462/06
HFD-0191: H-Field Probe-27MHz-1GHz
PURCHASE
AvailableQTYPrice
New:   2
+ -
$0.00
Used:   1
+ -
$0.00Configurations
X

Available Configurations

HFD-0191: H-FIELD PROBE-27MHZ-1GHZ
30023608
$0

The probe detects magnetic fields from 27 MHz up to 1 GHz. This wide frequency range for a magnetic field probe covers all the major areas of electromagnetic field exposure that can occur in radio and TV broadcasting, telecommunications, and in high frequency industrial applications. The probe is suitable for the detection of human exposure limits in the general public and occupational environments.

The probe’s interface digitally transmits the measurement data to the base unit, which has no individual influence on the measured values and therefore does not need to be calibrated. Probe calibration is carried out at several frequencies. The calibration data is stored in the probe and is automatically taken into account during the measurement. If the frequency of the predominating field strength is known, a correction factor can additionally be applied to increase the measurement accuracy.

  • Isotropic (non-directional) measurement
  • High dynamic range of 60 dB
  • Wide True RMS range up to 1 A/m
  • Digital probe interface - no more meter calibration
  • Self-test of the probe interface with integrated sensor function test
  • Automatic offset correction, no zero adjustment required
  • Wide temperature range from -20 °C to +50 °C
  • High Immunity at 50/60 Hz
  • Factory calibration up to 1 GHz
  • Manual
  • All additional standard accessories
  • Frequency Range: 27MHz to 1GHz
  • Response: flat
  • Compatibility: Fieldman
  • RF Safety
Description

The probe detects magnetic fields from 27 MHz up to 1 GHz. This wide frequency range for a magnetic field probe covers all the major areas of electromagnetic field exposure that can occur in radio and TV broadcasting, telecommunications, and in high frequency industrial applications. The probe is suitable for the detection of human exposure limits in the general public and occupational environments.

The probe’s interface digitally transmits the measurement data to the base unit, which has no individual influence on the measured values and therefore does not need to be calibrated. Probe calibration is carried out at several frequencies. The calibration data is stored in the probe and is automatically taken into account during the measurement. If the frequency of the predominating field strength is known, a correction factor can additionally be applied to increase the measurement accuracy.

  • Isotropic (non-directional) measurement
  • High dynamic range of 60 dB
  • Wide True RMS range up to 1 A/m
  • Digital probe interface - no more meter calibration
  • Self-test of the probe interface with integrated sensor function test
  • Automatic offset correction, no zero adjustment required
  • Wide temperature range from -20 °C to +50 °C
  • High Immunity at 50/60 Hz
  • Factory calibration up to 1 GHz