Close
You have no items in your shopping cart.

Teledyne LeCroy HDO4104 Oscilloscope

Manufacturer part number: HDO4104
Teledyne LeCroy HDO4104: 12-bit HD Oscilloscope with 12.1in WXGA Touch Display, 1GHz, 2.5GS/s, 4-Ch, 12.5Mpts/Ch
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   1
+ -
$0.00Configurations
X

Available Configurations

HI DEF OSCILLOSCOPE: 1GHZ, 2.5GS, 4 CH
30008837
$0

Teledyne LeCroy HDO4104: 12-bit HD Oscilloscope with 12.1in WXGA Touch Display, 1GHz, 2.5GS/s, 4-Ch, 12.5Mpts/Ch

The HDO4000-series High Definition Oscilloscopes combine Teledyne LeCroy's HD4096 high definition 12-bit technology with long memory, a compact form factor, 12.1 inch touch screen display, and powerful debug tools. The HDO4000 is the ideal oscilloscope for precise measurements and quick debug. Tools such as WaveScan Search and Find, LabNotebook Report Generator, and History Mode help identify and isolate problems for faster troubleshooting.

Key Features

  • 12-bit ADC resolution, up to 15-bit with enhanced resolution
  • 200MHz, 350MHz, 500MHz, and 1GHz bandwidths
  • Long Memory - up to 50Mpts/Ch
  • Multi-language User Interface
  • WaveScan - Advanced Search and Find
  • LabNotebook Documentation and Report Generation
  • History Mode - Waveform Playback
  • Spectrum Analyzer Mode
  • Power Analysis Software
  • Serial Data Trigger and Decode
  • Memory: up to 25Mpts/Ch (50Mpts interleaved)
  • Sample Rate: 2.5GS/s single-shot, 125GS/s repetitive
  • Display: 12.1-Inch Wide TFT-LCD Touch Screen
  • Connectivity: USB Host, USB Device, LAN, GPIB
  • ÷10 Passive Probe (Total of 1 Per Channel)
  • Getting Started Guide
  • Anti-virus Software (Trial Version)
  • Microsoft Windows Embedded Standard 7 P 64-Bit License
  • Commercial NIST Traceable Calibration with Certificate
  • Power Cable for the Destination Country

Vertical System

  • Bandwidth: 1GHz
  • Rise time: 450ps
  • Input Channels: four
  • Bandwidth Limiters: 20MHz, 200MHz
  • Input Impedance: 1MΩ ±2.0%, 15pF; 50Ω, ±2.0%
  • Input Coupling: AC, DC, GND
  • Maximum Input Voltage, 1MΩ: 400V max (DC + Peak AC ≤10kHz)
  • Maximum Input Voltage, 50Ω: 5VRMS
  • Channel-Channel Isolation: ≥24dB
  • Vertical Resolution: 12 bits
  • Sensitivity, 50Ω: 1mV/div to 1V/div
  • Sensitivity, 1MΩ: 1mV/div to 10V/div
  • DC Gain Accuracy, 50Ω: ±0.5% full scale, offset at 0V
  • DC Gain Accuracy; 50Ω, ±1.6V: 1mV/div to 4.95mV/div
  • DC Gain Accuracy; 50Ω, ±4V: 5mV/div to 9.9mV/div
  • DC Gain Accuracy; 50Ω, ±8V: 10mV/div to 19.8mV/div
  • DC Gain Accuracy; 50Ω, ±10V: 20mV/div to 1V/div
  • Offset Range; 1MΩ, ±1.6V: 1mV/div to 4.95mV/div
  • Offset Range; 1MΩ, ±4V: 5mV/div to 9.9mV/div
  • Offset Range; 1MΩ, ±8V: 10mV/div to 19.8mV/div
  • Offset Range; 1MΩ, ±16V: 20mV/div to 100mV/div
  • Offset Range; 1MΩ, ±80V: 102mV/div to 198mV/div
  • Offset Range; 1MΩ, ±160V: 200mV/div to 1V/div
  • Offset Range; 1MΩ, ±400V: 1.02V/div to 10V/div

Horizontal System

  • Time/Division Range: 200ps/div - 1.25ks/div with standard memory (up to 2.5ks/div with -L memory); RIS available at ≤10ns/div; Roll Mode available at ≥100ms/div and ≤5MS/s
  • Clock Accuracy: ±2.5ppm for 5 to 40°C + 1.0ppm/year from calibration
  • Trigger and Interpolator Jitter: 3.5ps rms

Acquisition System

  • Single-Shot Sample Rate/Ch: 2.5GS/s
  • Equivalent Sample Rate: 125GS/s
  • Memory: 25Mpts/Ch on 1 Ch, 12.5Mpts/Ch on 2 Ch, 12.5Mpts/Ch on 4 Ch
  • Averaging: Up to 1,000,000
  • Interpolation: Linear, Sin x/x
  • Enhanced Resolution: Up to 15 bits
  • Sequence Mode: Up to 10,000 segments

Triggering System

  • Modes Normal, Auto, Single, Stop
  • Sources: Ch 1 through Ch 4, EXT, EXT/10, AC Line
  • Coupling Mode: AC, DC, LF Rej, HF Rej
  • Pre-trigger Delay: 0 to 100% of full scale
  • Post-trigger Delay: 0 to 10,000 Divisions
  • Hold-off by Time or Events: 2ns up to 20s
  • Internal Trigger Range: ±4.1 Divisions
  • Trigger Sensitivity, 0.9 division: 10MHz
  • Trigger Sensitivity, 1.0 divisions: 200MHz
  • Trigger Sensitivity, 1.5 divisions: 500MHz
  • Trigger Sensitivity, 2.0 divisions: 1GHz
  • External Trigger Sensitivity, 0.9 division: 10MHz
  • External Trigger Sensitivity1.0 divisions, : 200MHz
  • External Trigger Sensitivity, 1.5 divisions: 500MHz
  • External Trigger Sensitivity, 2.0 divisions: 1GHz
  • External Trigger Input Range Ext: ±0.4 V, EXT/10: ±4.0 V
  • Triggers: Edge, Glitch, Width, Logic (Pattern), TV (NTSC, PAL, SECAM, HDTV), Runt, Slew Rate, Interval, Dropout, Qualified
  • Optional Serial Data Triggers: I2C, SPI, UART/RS-232, CAN, LIN, FlexRay, SENT, MIL-STD-1553, ARINC 429, Audio (I2S, LJ, RJ, TDM), USB, USB-HSIC, MIPI D-PHY, DigRF3G

Internal Storage

  • Media: internal hard drive, RAM
  • Waveform Storage: four waveforms
  • Setup Storage: six setups

Math

  • Number of Math Traces: two
  • Standard Math Functions: Add, Subtract, Multiply, Divide, FFT, Absolute Value, Averaging (summed and continuous), Derivative, Envelope, Enhanced Resolution, Floor, Integral, Invert, Reciprocal, Rescale, Roof, Square, Square Root, Trend, Zoom

Measurements

  • Number of Measurements Displayed: eight
  • Measurement Parameters: Amplitude, Area, Base, Delay, Delta Period @ Level, Delta Time @ Level, Duty Cycle, Duty @ Level, Edge @ Level, Fall Time (90% to 10%), Fall Time (80% to 20%), Frequency, Frequency @ Level, Maximum, Mean, Minimum, Overshoot+, Overshoot-, Period, Peak-Peak, Period, Period @ Level, Phase, Rise Time (10% to 90%), Rise Time (20% to 80%), RMS, Skew, Standard Deviation, Time @ Level, Top, Width+, Width-

Probes

  • Quantity: four ÷10 Passive Probes
  • Scale Factors, Automatic/Manual: ÷1, ÷10, ÷20, ÷100, ÷200, ÷1000, ÷2000, ÷10000
  • Scale Factors, Variable: (÷1x10-6 to ÷10000)
  • Calibration Output: 1kHz square wave, 1.0Vp-p, output to probe hook

Interface

  • USB (Host): six
  • USB (Device): one
  • Ethernet Port: one
  • GPIB Port: one (optional)

Mains

  • Power Requirement: 90 to 264VAC @ 45Hz to 66Hz; 90 to 132VAC @ 380Hz to 420Hz
  • Max. Power Consumption: 75VA

Description

Teledyne LeCroy HDO4104: 12-bit HD Oscilloscope with 12.1in WXGA Touch Display, 1GHz, 2.5GS/s, 4-Ch, 12.5Mpts/Ch

The HDO4000-series High Definition Oscilloscopes combine Teledyne LeCroy's HD4096 high definition 12-bit technology with long memory, a compact form factor, 12.1 inch touch screen display, and powerful debug tools. The HDO4000 is the ideal oscilloscope for precise measurements and quick debug. Tools such as WaveScan Search and Find, LabNotebook Report Generator, and History Mode help identify and isolate problems for faster troubleshooting.

Key Features

  • 12-bit ADC resolution, up to 15-bit with enhanced resolution
  • 200MHz, 350MHz, 500MHz, and 1GHz bandwidths
  • Long Memory - up to 50Mpts/Ch
  • Multi-language User Interface
  • WaveScan - Advanced Search and Find
  • LabNotebook Documentation and Report Generation
  • History Mode - Waveform Playback
  • Spectrum Analyzer Mode
  • Power Analysis Software
  • Serial Data Trigger and Decode
  • Memory: up to 25Mpts/Ch (50Mpts interleaved)
  • Sample Rate: 2.5GS/s single-shot, 125GS/s repetitive
  • Display: 12.1-Inch Wide TFT-LCD Touch Screen
  • Connectivity: USB Host, USB Device, LAN, GPIB
Product tags