Haefely AXOS8 Compact Immunity Test System, 7 kV integrates all of the best features of several stand-alone test systems into one single economic solution. Standards: IEC/EN 61000-4-4, -4-5, -4-9, -4-11, -4-12
PURCHASE
Available QTY Price
New:   0
+ -
$0.00
Used:   0
+ -
$0.00 Configurations
X

Available Configurations

OPTIONS
Name Purchase
Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5 $0.00
Ring Wave IEEE C62.41 $0.00
EFT/Burst IEC/EN 61000-4-4 $0.00
Voltage Dips IEC/EN 61000-4-11** $0.00
Magnetic Field IEC/EN 61000-4-9*** $0.00

Key Features and Functions

The Haefely AXOS8 Expandable EMC Immunity Test System integrates all of the best features of several stand alone test systems into one single economic solution. It can be individually combined either with 7kV Surge Combination Wave, 7kV Ring Wave, 7kV Telecom Wave, 5kV EFT/Burst or Dips & Interrupts, along with an integrated singlephase coupling/decoupling network. This allows quick and completely automated testing to the most common IEC, EN, ANSI, ITU, IEEE, and UL standards.

The AXOS8 can either be operated via front panel by large colour graphic interface or remotely from a PC. The easy to use menu together with the availability of predefined test routines for different standards makes testing easy and reliable, even for less frequently users. Numerous additional functions such as external start/stop function allows easy integration of the test system also in customer specific test environments.

All the test parameters can be varied in a broad range wide above the requirements of the standards. Together with the ability of changing test parameters during test, AXOS8 is not only the ideal product for compliance and pre-compliance testing, it is useful for monitoring & debugging function during design phase as well.

A wide range of cost-efficient and user friendly coupling / decoupling networks for power lines as well as for symmetrical and asymmetrical data- and signal lines are available as options.

Features:

  • Easy to operate with manual and automated test modes, software assisted test preparation, pre-defined test routines and visual aided test setups
  • Economic & Efficient: Touch screen guarantees reduction of time and effort - Experience and know-how at a reasonable price
  • Safe and reliable operation by using safety interlock, warning lamp and emergency stop functions
  • Voltage and current monitoring of surge impulses and EUT power provides valuable feedback to the test engineer
  • Automatic generation of test report, including test parameters, test setup and test result

Standards:

  • IEC/EN 61000-4-4 EFT/Burst
  • IEC/EN 61000-4-5 Surge Edition 2 & 3 (1.2/50µs...8/20µs)
  • IEC/EN 61000-4-5 Surge (10/700µs)*
  • IEC/EN 61000-4-9 Magnetic Field**
  • IEC/EN 61000-4-11 AC Dips and Interrupts***
  • IEC/EN 61000-4-12 Ring Wave
  • IEC/EN 61000-4-29 DC Dips and Interrupts
  • IEC/EN 61000-6-1 Generic Residential
  • IEC/EN 61000-6-2 Generic Industrial
  • IEC/EN 60335-1 Household
  • IEC/EN 60601-1 Medical
  • IEC/EN 60950
  • EN 55024
  • IEEE C62.41
  • ITU K.20, K.21, K.44, K.45
  • Manual
  • Calibration Certificate
  • Telecom Wave Module TS 8; 10/700µs (only with AXOS8 Telecom Wave Test System catalogue# 2490850)
  • All standard accessories

General Specifications

  • User test storage: unlimited
  • Remote interface: Ethernet, RJ45
  • External memory: USB for USB memory stick
  • Display: 7in, 800x480, 24-bit, touch-screen
  • AUX interface: D-sub 37p for external CDN, external transformer etc
  • External trigger input: 5V TTL
  • Synch input: BNC, 10V to 264VAC
  • Trigger output: 5V TTL
  • External start/stop input: 5V TTL, starts/stops predefined test sequence
  • EUT failed input: 5V TTL
  • Analog output: 0 to 10V, for use with external options
  • Safety circuit: stops the test when unlocked
  • Control power: 85VAC to 264VAC, 50/60Hz
  • Dimensions, (W x H x D): 45 x 27 x 50cm; 22in/6U
  • Weight: 30kg

IEC/EN 61000-4-4 EDITION 2 & 3 EFT/BURST

  • Output voltage: 0.2 to 5.0kV ±10% at coaxial output
  • Spike frequency: 1Hz to 1MHz
  • Polarity: pos/neg/alternate
  • Burst duration: 10µs to 1s
  • Output impedance: 50Ω
  • Burst period: 1ms to 10s
  • Rise time: 5ns ±30%
  • Test time: 1s to 1000 minutes
  • Impulse duration at 50Ω: 50ns ±30%
  • Impulse duration at 1000Ω:50ns -15 +100ns
  • Trigger: automatic, manual, external trigger input
  • Burst mode: normal, continuous, real, random
  • Integrated single phase coupling/decoupling network: 264VAC/16A; 220VDC/10A

IEC / EN 61000-4-5 EDITION 2 & UPCOMING EDITION 3 SURGE COMBINATION WAVE

  • Output voltage 0.2 to 5.0kV ±10%
  • Output current: 0.1 to 3.5kA ±10%
  • Voltage rise time: 1.2µs ±30%
  • Current rise time: 8µs ±20%
  • Voltage duration: 50µs ±20%
  • Current duration: 20µs ±20%
  • Polarity: pos/neg/alternate
  • Output impedance: 2Ω
  • Integrated single phase CDN: 264VAC/16A; 220VDC/10A
  • Phase sync: 0 to 359° with 1° steps or asynchronous mode
  • Impulse trigger: automatic 2s to 100 min, manual, external trigger input
  • Counter preselect: 1 to 1000/infinite
  • Counter: 100000
  • Peak voltage monitor: BNC output, 1000:1; display, 3 digits
  • Peak current monitor: BNC output, 1kA/V; display, 3 digits

IEC/EN 61000-4-5 Telecom Wave/ITU K.20, K.21, K.44, K.45

  • Max voltage: 0.2 to 7.0kV ±10%
  • Front time, OC: 10µs ±30%
  • Decay time OC: 700µs ±20%
  • Undershoot OC: <30%
  • Front time SC: 5µs ±20%
  • Decay time SC 320µs ±20%
  • Undershoot SC: <30%
  • Source impedance/coupling: 15Ω, 40Ω, 40Ω gas arrestors
  • Outputs: 1 x 15Ω direct, 4 x 40Ω direct, 4 x 40Ω gas arrestors
  • Impulse output: Banana connector
  • Impulse input: HV connector
  • Transitions: V, Polarity
  • Number of events: 1 to 10,000
  • Repetition rate: up to 30/min
  • Polarity: Positive/negative/alternate
  • Weight: 10kg

IEC/EN 61000-4-11 EDITION 2 AND IEC/EN 61000-4-29 DIPS & INTERRUPTS

  • Max voltage: 264VAC/DC
  • Interrupt time: 0.5 period to 800 periods, 100µs to 1000 minutes
  • Max current: 16A AC/DC continuous
  • Max current for 5s: 20A
  • Max current for 3s: 23A
  • Max current for 3s:40A >500A inrush current
  • Interval time 1: period to 800 periods synch; 100µs to 1000 minutes asynch
  • Trigger: automatic, manual, external trigger input
  • Test time: 1s to 1000 minutes, infinite
  • Interrupt dip level: 0%, 0% to 99% with external voltage source
  • Phase sync: 0 to 359° 16/40/50/60Hz asynchronous mode

IEC/EN 61000-4-12 AND IEEE C62.41 Ring Wave

  • Max voltage: 0.2 to 7.0kV ±10%
  • Repetition rate: Up to 30 pulses/min
  • Frequency: 100kHz
  • Polarity: Positive/negative/alternate
  • Rise time, OC: 0.5µs
  • Rise time, SC: 1µs
  • Phase sync accuracy: ±1°
  • Floating output: 460VAC max
  • Impedance: 12Ω, 30Ω
  • Damping rate: 60% of previous peak

Description

Key Features and Functions

The Haefely AXOS8 Expandable EMC Immunity Test System integrates all of the best features of several stand alone test systems into one single economic solution. It can be individually combined either with 7kV Surge Combination Wave, 7kV Ring Wave, 7kV Telecom Wave, 5kV EFT/Burst or Dips & Interrupts, along with an integrated singlephase coupling/decoupling network. This allows quick and completely automated testing to the most common IEC, EN, ANSI, ITU, IEEE, and UL standards.

The AXOS8 can either be operated via front panel by large colour graphic interface or remotely from a PC. The easy to use menu together with the availability of predefined test routines for different standards makes testing easy and reliable, even for less frequently users. Numerous additional functions such as external start/stop function allows easy integration of the test system also in customer specific test environments.

All the test parameters can be varied in a broad range wide above the requirements of the standards. Together with the ability of changing test parameters during test, AXOS8 is not only the ideal product for compliance and pre-compliance testing, it is useful for monitoring & debugging function during design phase as well.

A wide range of cost-efficient and user friendly coupling / decoupling networks for power lines as well as for symmetrical and asymmetrical data- and signal lines are available as options.

Features:

  • Easy to operate with manual and automated test modes, software assisted test preparation, pre-defined test routines and visual aided test setups
  • Economic & Efficient: Touch screen guarantees reduction of time and effort - Experience and know-how at a reasonable price
  • Safe and reliable operation by using safety interlock, warning lamp and emergency stop functions
  • Voltage and current monitoring of surge impulses and EUT power provides valuable feedback to the test engineer
  • Automatic generation of test report, including test parameters, test setup and test result

Standards:

  • IEC/EN 61000-4-4 EFT/Burst
  • IEC/EN 61000-4-5 Surge Edition 2 & 3 (1.2/50µs...8/20µs)
  • IEC/EN 61000-4-5 Surge (10/700µs)*
  • IEC/EN 61000-4-9 Magnetic Field**
  • IEC/EN 61000-4-11 AC Dips and Interrupts***
  • IEC/EN 61000-4-12 Ring Wave
  • IEC/EN 61000-4-29 DC Dips and Interrupts
  • IEC/EN 61000-6-1 Generic Residential
  • IEC/EN 61000-6-2 Generic Industrial
  • IEC/EN 60335-1 Household
  • IEC/EN 60601-1 Medical
  • IEC/EN 60950
  • EN 55024
  • IEEE C62.41
  • ITU K.20, K.21, K.44, K.45