Fluke 5700A Multifunction Calibrator

Manufacturer part number: 5700A
DC voltage to 1100V
PURCHASE
Available QTY Price
New:   0
+ -
$0.00
Used:   0
+ -
$0.00 Configurations
X

Available Configurations

OPTIONS
Name Purchase
MET BASE SW (REQUIRES MET CAL LIC) $0.00
METBASE 7 SOFTWARE $0.00
LICENSE METCAL SOFTWARE $0.00
CAL LICENSE $0.00
RACK KIT $0.00
REAR PANEL OUTPUT (FT. PANEL DISABLED) $0.00
WIDE BAND AC VOLTAGE $0.00
115 AC VOLTAGE $0.00
LEADS $0.00
MANUAL (SERVICE) $0.00
ISO 9000 CAL KIT W/IEEE $0.00

Key Features and Functions

The 5700A is a five-function calibrator designed to address the most demanding electrical calibration workload. Source direct and alternating voltage and current and resistance with the Fluke 5700A. Considered the calibration standard worldwide, the 5700A delivers high value as well as accuracy covering 5 1/2 to 7 1/2 digit dmms. The 5700A features Artifact Calibration. Only three artifact standards -- a 10V dc reference and 1Ω and 10 kΩ resistance references are required to calibrate all ranges and functions to full specifications. Front panel instructions prompt the operator to make connections and inputs each step of the way. The calibrator controls the process, which takes only about an hour, compared to several hours using traditional methods.

To assure confidence, the 5700A can check itself against its own internal standards to assure everything is working as expected. Those results can be printed out or downloaded to a computer.

 

 

General Specifications
Warm up Time
   2x the time since last warmed up, to a maximum of 30 minutes
System Installation
   Rear output configuration and rack-mount kit available
Interfaces
   IEEE-488, RS-232, 5725A, 5205A or 5215A, 5220A, phase lock in (BNC), phase reference out (BNC)
Temperature Performance
Operating:  0°C to 50°C
Calibration:  15°C to 35°C
Storage:  -40°C to 75°C
Relative Humidity
Operating:  < 80% to 30°C, < 70% to 40°C, < 40% to 50°C
Storage:  < 95%, non-condensing. A power-on stabilization period of four days may be required after extended storage at high temperature and humidity.
Safety
   Designed to comply with UL311; IEC 348-1978; IEC 66E (CO)4; CSA 556B
Guard isolation
   20 volts
EMI/RFI
   Designed to comply with FCC Rules Part 15, Subpart J, Class B; VDE 0871, Class B
Line Power
   47 to 63 Hz; + 10% allowed about selectable nominal line voltage: 100V, 110V, 115V, 120V, 200V, 220V, 230V, 240V
   --------------
Maximum power:  5700A/5720A: 300 VA;5725A, 750 VA
Calibration Documentation 17025 accredited report of calibration included
Size
5700A/5720A:  Height 17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet; width 43.2 cm (17 in), standard rack width; depth 63.0 cm (24.8 in) overall; 57.8 cm (22.7 in), rack depth
5725A:  Height 13.3 cm (5.25 in); width and depth same as 5700A/5720A
   Both units project 5.2 cm, (2 in) from rack front
Weight
5700A/5720A:  27 kg (62 lbs.)
5725A:  32 kg (70 lbs.)
Description

Key Features and Functions

The 5700A is a five-function calibrator designed to address the most demanding electrical calibration workload. Source direct and alternating voltage and current and resistance with the Fluke 5700A. Considered the calibration standard worldwide, the 5700A delivers high value as well as accuracy covering 5 1/2 to 7 1/2 digit dmms. The 5700A features Artifact Calibration. Only three artifact standards -- a 10V dc reference and 1Ω and 10 kΩ resistance references are required to calibrate all ranges and functions to full specifications. Front panel instructions prompt the operator to make connections and inputs each step of the way. The calibrator controls the process, which takes only about an hour, compared to several hours using traditional methods.

To assure confidence, the 5700A can check itself against its own internal standards to assure everything is working as expected. Those results can be printed out or downloaded to a computer.