Fischer FCC-BCICF-2 Bulk Current Injection Probe Fixtures

Manufacturer part number: FCC-BCICF-2
10 kHz – 1 GHz Frequency Injection Probe Model Numbers: F-140, F-140A Injection Probe Calibration Fixtures Part of the test equipment required by most of the Bulk Current Injection test procedure specifications Test fixture allows the user to quickly and easily calibrate the injection probe
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

TEST EQUIPMENT DESCRIPTION

Injection Probe calibration fixtures are a part of the test equipment required by most of the Bulk Current Injection Test Procedure Specifications. This test fixture allows the user to quickly and easily calibrate the injection probe prior to performing the compliance testing.

This calibration fixture offers two important benefits.

  1. Due to variable circuit impedances or resonances in cables and cable looms, the calibration fixture is used to establish the forward power into the injection probe needed to develop the specified currents in the system under test.
  2. The fixture can be used to measure the injection probes insertion loss.
Description

TEST EQUIPMENT DESCRIPTION

Injection Probe calibration fixtures are a part of the test equipment required by most of the Bulk Current Injection Test Procedure Specifications. This test fixture allows the user to quickly and easily calibrate the injection probe prior to performing the compliance testing.

This calibration fixture offers two important benefits.

  1. Due to variable circuit impedances or resonances in cables and cable looms, the calibration fixture is used to establish the forward power into the injection probe needed to develop the specified currents in the system under test.
  2. The fixture can be used to measure the injection probes insertion loss.