EM Test CWS 500N1.4 Test Generator

Manufacturer part number: CWS-500N1.4
RF Conducted Immunity Test System
PURCHASE
Available QTY Price
New:   0
+ -
$0.00
Used:   0
+ -
$0.00 Configurations
X

Available Configurations

The CWS 500N1.4 is the most compact single box test equipment for testing conducted rf immunity per IEC 61000-4-6 Ed. 3 and Ed. 4 and related standards with a frequency range of 100 kHz to 300 MHz. Apart from the 1 kHz 80 % AM signal the generator also generates a 2 Hz 80 % AM signal to test medical appliances and a 1 Hz PM signal with a 50% duty cycle required to test safety equipment like fire alarms. Equipped with a 1 GHz current monitor the CWS 500N1.4 can be used up to 1 GHz by means of an external amplifier. EM TEST supplies a large range of CDNs, EM clamp, and current injection clamps as well as the corresponding calibration accessories. Full compliant leveling can be run from the front panel of the CWS 500N1.4 storing the results in 5 memory spaces is available.
 
Features:
  • Test procedure acc. IEC 61000-4-6 Ed. 4
  • Built-in amplifier saturation and linearity check
  • Built-in power amplifier 25 to 80 watts, 10 kHz to 400 MHz
  • Built-in power meter, 9 kHz to 1 GHz
  • Built-in dual directional coupler
  • Automatic calibration via a built-in power meter
  • Connection for external amplifiers up to 1 GHz
  • USB-Interface
  • Software for Windows 7, Windows 8

Test Level CWS 500N1.3

Output Level

1 - 30Ve.m.f. after 6dB-attenuator

Output power

80W (nominal)

Output impedance

50 Ohm

max. VSWR

1:1.2 at all phase angles and at max. power (without destruction)

Harmonic distortion
(at max. power)

< 15dBc

Test frequencies

CWS 500N1.3

CWS 500N1.4

Sinusoidal (CW)

10 kHz – 400 MHz

               100 kHz – 300 MHz   step: 1kHz

 

In the menu QUICK START the step size can be selected by the user

Modulation

Modulation method

Amplitude modulation
80% <±5% and 1kHz <±10% acc. to IEC 61000-4-6
80% <±5% and 2Hz, 1kHz acc. to IEC 60601-1-2

Pulse modulation

1Hz, 50% duty cycle acc. to EN 50130-4

General

80% at Frequencies 2Hz, 400Hz,1kHz

Other modulation

via ICD software Settings in Vector mode

Signal Generator

Output level

-63.5 dBm to 0 dBm

Step level

0.5 dB

Frequency range

9 kHz to 1 GHz

Output impedance

50 ohm

Calibration measurements

Cal data

5 internal stores for calibration data.

ICD

Software for the upload and download of Cal-files.

LCD

On-line display of the test level and the preselected frequencies.

Monitor input PM1000

RF monitor input for calibration procedures and current probes measurement. Input voltage for current monitoring V max = 1.0 V rms (13dBm)

Cal data for current probe (CP)

2 internal stores ; ( download with ICD software )
A download will reduce data to 10/ decade and frequency range 100kHz ... 300MHz

Timing

Dwell time

general td = 0,3s - 9999.9s
pulse modulation td = 3s - 9999.9s

Rest time

tr = 0 / 0,3s - 9999.9s

Output

Direct

N

EUT control

BNC input

FAIL 1 Fail 1; test will be stopped immediately

BNC input

FAIL 2 Fail 2; failure is detected, test continues (max. 10 failures)

Test routines (integrated)

Quick Start

Immediate start, all parameters adjustable during testing.

User test routines

1. Voltage sweep
2. Frequency sweep
3. Dwell time sweep

Standard test routines.

1. Level 1-3 acc. to IEC 61000-4-6
2. Automatic Level X - Level Y

Cal procedure

Calibration of the complete test set-up. Internal storage of the Cal-files.

Service

Service, Setup

Interfaces

Serial Interface

USB

Parallel IEEE 488 GPIB interface

Addresses 1 - 30 selectable
All interfaces are included as standard features.

Power meter PM 1000

Frequency range

9kHz – 1000 MHz

Input range

Monitor -45 dBm ... +13 dBm
FWD power -50 dBm ... +13 dBm
REV power -50 dBm ... +13 dBm

Max. Input MONITOR

13dBm approx. 1.0 Vrms

Accuracy

< ± 0.5 dB ( 0.09MHz...400MHz )
< ± 1.0 dB ( 0.01MHz...1000MHz )

Dual Directional Coupler

Frequency range

10kHz – 1000 MHz

Power

150 W max.

Insertion loss

0.6 dB max.

Mainline VSWR

1.1:1 max.

RF Amplifier ( build in )

CWS 500N1.3

CWS 500N1.4

Class of Operation

Class A

Class A

Frequency range

10 kHz .. 400 MHz

100 kHz .. 300 MHz

Output power nominal

80 W

80 W

Gain

48 dB nominal

48 dB nominal

Input power for rated output

0 dBm

0 dBm

Input power max.

10 dBm

10 dBm

Input / Output Impedance

50 Ω

50 Ω

Input VSWR

1.5: 1 max.

1.5: 1 max.

General Data

Dimensions

19"/3HE

19"/3HE

Weight

17.25 kg

14.95 kg

Power supply

110-230V/ max 50/60Hz

Input power

max. 380W

Power factor

cosΦ=0,98 at max output power

acc. to IEC 555

Fuse

230V: 2x3,15AT
115V: 2x6.3AT

Cooling

Active cooling, air ventilation

Environment conditions

10°C - 35°C

10°C - 40°C

Humidity

Max. 85 %, non-condensing

Description
The CWS 500N1.4 is the most compact single box test equipment for testing conducted rf immunity per IEC 61000-4-6 Ed. 3 and Ed. 4 and related standards with a frequency range of 100 kHz to 300 MHz. Apart from the 1 kHz 80 % AM signal the generator also generates a 2 Hz 80 % AM signal to test medical appliances and a 1 Hz PM signal with a 50% duty cycle required to test safety equipment like fire alarms. Equipped with a 1 GHz current monitor the CWS 500N1.4 can be used up to 1 GHz by means of an external amplifier. EM TEST supplies a large range of CDNs, EM clamp, and current injection clamps as well as the corresponding calibration accessories. Full compliant leveling can be run from the front panel of the CWS 500N1.4 storing the results in 5 memory spaces is available.
 
Features:
  • Test procedure acc. IEC 61000-4-6 Ed. 4
  • Built-in amplifier saturation and linearity check
  • Built-in power amplifier 25 to 80 watts, 10 kHz to 400 MHz
  • Built-in power meter, 9 kHz to 1 GHz
  • Built-in dual directional coupler
  • Automatic calibration via a built-in power meter
  • Connection for external amplifiers up to 1 GHz
  • USB-Interface
  • Software for Windows 7, Windows 8