Electrical Specifications
- Burst Polarity: Positive, negative, alternating
- Burst Voltage: 200V to 8.0kV, ±10%; 5V resolution
- Burst Frequency: Adjustable from 1kHz to 1MHz up to 4.4kV; 1kHz to 250kHz from 4.4kV to 8.0kV
- Burst Duration: 1.0ms to 20ms; 1.0ms resolution
- Period Between Bursts: Adjustable from 300ms to 5s; 1ms resolution
- Voltage Monitor: Built-in; 150MHz bandwidth
- Minimum System Requirements: E100 series control center
Burst Test Length
- 1 to 360 sec.; 1 second resolution
- 1 to 240 min.; 1 minute resolution
- 1 to 24 hours; 1 hour resolution
Wait Time Between Tests
- 1 to 360 sec.; 1 second resolution
- 1 to 240 min.; 1 minute resolution
- 1 to 24 hours; 1 hour resolution
Options
- Coupler/decoupler: Thermo Scientific model E455X
- E421-2MHz: increases EFT burst frequency to 2MHz @ ≤3kV
- E411-CH: adds Chirp
- CCL: capacitive coupling clamp per IEC 61000-4-4
Note: For any combination of frequency, duration and period, the number of pulses can not exceed 600 per second and 200 per burst.