Manufacturer part number: HT-3500S-RF
Adjustable Ground Continuity, Portable and Rugged. 0-2500Vac @ 20mA, 0-3500Vdc @ 5mA
PURCHASE
Available QTY Price
New:   0
+ -
$0.00
Used:   0
+ -
$0.00 Configurations
X

Available Configurations

OPTIONS
Name Purchase
High Voltage Test Lead, 5KV, Red 4ft long $0.00
High Voltage Test Lead, 5KV, Red 6ft long $0.00
Relay Interface/PLC Interface $0.00
Auto Reset on Pass option $0.00
Function Checker: HTT-1 (Tester Function) $0.00
Function Checker: HTT-1R (Tester/Cal Function) $0.00

Key Features and Functions

Compliance West introduces their Rugged Hipot Tester, the HT-3500S-RF.  It is encased in a shipping enclosure roomy enough for cables or a DVM, with all controls accessible without removing it from the enclosure.

  • High precision leakage current, duration and ground continuity settings.
  • Allows no load setup of leakage current and test dwell times.
  • Once entered, ground continuity setting, leakage current and test dwell times can be referenced on the front panel display when unit is not testing.
  • Leakage currents can be set from 1-20 mA AC or 1-5 mA DC in 0.1mA increments.
  • Dwell times can be set from 1-60 seconds in 1 second increments.
  • Two tests with one setup. Conducts UL/CSA Ground continuity and Hipot tests with one setup, so no additional equipment is needed.
  • Small and light. 9.25" wide x 4.75" high x 10" deep. 14 lbs. But rugged enough to test manufactured housing.
  • Ground continuity check is defeatable for testing two-wire products.
  • Easy equipment connections. Plug your equipment right into the NEMA plug on the front panel. No adapters needed!
  • J2 and J3 cords allow connection of pigtail power leads.
  • Simple test outcome judgement. Green lights mean pass - red lights mean fail. Failing tests sound a buzzer as well.
  • Ready for your UL Inspector out of the box. NIST Traceable Calibration Certificate to MIL-STD45662-A is included. Cal cert is in accordance with UL guidance.
  • Operation Instructions are printed on the rear panel for easy reference.
  • In-depth testing. Both true Arc Dectection and Leakage Current circuits test the product to find problems.
  • RED lights and a buzzer leave no question if a failure has occurred.
  • Expandable for TUV/European Agency Testing. Can be connected to our GF-30ac 25A Ground Bond Tester with optional TEST-LINK™.
  • Easy shift-by-shift Function Test. Compatible with our Patented function checker, the HTT-1and HTT-1R (With 0.1 ohm Ground check Pass/Fail Setup).
Voltage Range 0-2500 AC 0-3500 DC
Leakage Current Set Point 1-20 mA AC 1-5 mA DC
Input Voltage Requirements 117-127 V, 50 /60 Hz
Fuse Requirements 120 V, 2 A Slow Blow
Arc Detect Independent High Frequency Circuit
Leakage Detect Independent Low Frequency Circuit
Ground Continuity Set Point 0.08 Ω - 1.50 Ω, Defeatable
Ground Continuity Test Current 100 mA
Test Time Range 1 - 60 Seconds
Ramp Time Range 1 - 5 Seconds
Voltage Meter Accuracy ± 2 %
HV Shutdown by Ground Fail < 7 mS
Duty Cycle 100%
Discharge Time < 7 mS VAC
Discharge Time < 1.3 Sec VDC at open circuit
Transformer Power < 500 VA
Pass/Fail Repeatability ± 3 %
Output Connector NEMA plug, High Voltage Test Jack
Display 4 digits LED display
Test Indicator Led indicators
Failure Indicator Led indicators and buzzer
Programable No
PLC Interface Optional
TestLink (With GF-30AC) Optional
Computer Control No
Voltage Hold on failure No
Top Mounted Handle Optional
Test Defeat Ground Continuity
Autoreset on Pass Optional
Operation Temperature 15 - 40 °C
Relative Humidity Range 0 - 90 % Non-condensing
Dimensions 9-1/4" wide x 4-3/4" high x 10" deep
Weight 14 Lbs
Calibration One year calibration Certificate
Test Cords Return Lead, Power Cord
Test Cords Ground Continuity Connector Tip
Test Cords J2 and J3 Optional
Test Cords Alligator Clip
Description

Key Features and Functions

Compliance West introduces their Rugged Hipot Tester, the HT-3500S-RF.  It is encased in a shipping enclosure roomy enough for cables or a DVM, with all controls accessible without removing it from the enclosure.

  • High precision leakage current, duration and ground continuity settings.
  • Allows no load setup of leakage current and test dwell times.
  • Once entered, ground continuity setting, leakage current and test dwell times can be referenced on the front panel display when unit is not testing.
  • Leakage currents can be set from 1-20 mA AC or 1-5 mA DC in 0.1mA increments.
  • Dwell times can be set from 1-60 seconds in 1 second increments.
  • Two tests with one setup. Conducts UL/CSA Ground continuity and Hipot tests with one setup, so no additional equipment is needed.
  • Small and light. 9.25" wide x 4.75" high x 10" deep. 14 lbs. But rugged enough to test manufactured housing.
  • Ground continuity check is defeatable for testing two-wire products.
  • Easy equipment connections. Plug your equipment right into the NEMA plug on the front panel. No adapters needed!
  • J2 and J3 cords allow connection of pigtail power leads.
  • Simple test outcome judgement. Green lights mean pass - red lights mean fail. Failing tests sound a buzzer as well.
  • Ready for your UL Inspector out of the box. NIST Traceable Calibration Certificate to MIL-STD45662-A is included. Cal cert is in accordance with UL guidance.
  • Operation Instructions are printed on the rear panel for easy reference.
  • In-depth testing. Both true Arc Dectection and Leakage Current circuits test the product to find problems.
  • RED lights and a buzzer leave no question if a failure has occurred.
  • Expandable for TUV/European Agency Testing. Can be connected to our GF-30ac 25A Ground Bond Tester with optional TEST-LINK™.
  • Easy shift-by-shift Function Test. Compatible with our Patented function checker, the HTT-1and HTT-1R (With 0.1 ohm Ground check Pass/Fail Setup).