Close
You have no items in your shopping cart.

Compliance West HT-10KVP AC/DC Hipot Tester

Manufacturer part number: HT-10KVP AC/DC
0-10KVac @ 10mA / 0-14KVdc @ 5 mA
PURCHASE
Available QTY Price
New:   0
+ -
$0.00
Used:   0
+ -
$0.00 Configurations
X

Available Configurations

Key Features and Functions 

  • HT10000P AC: AC output to 10000 Volts. Delivers 1 through 8 milliamps. Custom outputs to 25 mA.
  • HT10000P DC: DC output to 14000 Volts. Delivers 1 through 5 milliamps.
  • Logic Controlled, One-button testing. LED indicators. Buzzer upon failure, test terminates. Test termination defeatable by switch on rear panel. Provided with arc detection circuit to properly detect hipot failures.
  • Rear panel adjustments; leakage limit, ramp time, test time and voltage.
  • Ergonomic design for safety and ease of use.
  • High voltage output jack.
  • Automatic voltage ramp-down circuit eliminates residual voltage.
  • Designed for product development and laboratory use.
  • High efficiency design, low power consumption.
  • All test leads included.
  • Calibrated to NIST standards.
  • HTT-1 and HTT-1RHipot and Ground Continuity Function Checker Compatible
Voltage Range 0-10000 VAC 0-14000 VDC
Current Range 3 mA at 10 KVAC 1 mA at 14 KVDC
Input Voltage Requirements 108-132 V, 50 /60 Hz, 2A max
Fuse Requirements 120 VAC
Arc Detect Separate high Frequency circuit
Leakage Detect Separate Low frequency circuit
Ground Continuity N/A
Ground Continuity Current N/A
Test Time Range 1 - 60 seconds
Ramp time Range 1 - 5 Seconds
Voltage Meter Accuracy ± 2 %
Current Meter Accuracy ±0.1 mA
Resistance measure Range N/A
Resistance auto offset Range N/A
Resistance Measure Accuracy N/A
HV shutdown by Ground Fail N/A
Duty cycle 100%
Discharge Time (Resistive Load)  
Transformer Output < 500 VAC
Pass/Fail Repeatability ± 3 %
Output connector High Voltage Jack
Display 4 digits LED display
Test indicator Led indicators
Failure Indicator Led indicators and buzzer
Programable No
PLC Interface No
TestLink N/A
Testminder No
Voltage Hold on failure Available
Top Mounted handle No
Test Defeat Ramp Time, Test Time and Breakdown Fail
Autoreset on Pass Optional
Operation Temperature 15 - 40 °C
Relative Humidity Range 0 - 90 % Non-condensing
Dimensions 17" Wide x 5 High x 16.75 " Deep
Weight 31 lB
Calibration One year calibration Certificate
Test Cords Return lead, High Voltage Test Lead, Power cord
HTS/Schedule B 9030.39.0100
ECCN 3B992
Description

Key Features and Functions 

  • HT10000P AC: AC output to 10000 Volts. Delivers 1 through 8 milliamps. Custom outputs to 25 mA.
  • HT10000P DC: DC output to 14000 Volts. Delivers 1 through 5 milliamps.
  • Logic Controlled, One-button testing. LED indicators. Buzzer upon failure, test terminates. Test termination defeatable by switch on rear panel. Provided with arc detection circuit to properly detect hipot failures.
  • Rear panel adjustments; leakage limit, ramp time, test time and voltage.
  • Ergonomic design for safety and ease of use.
  • High voltage output jack.
  • Automatic voltage ramp-down circuit eliminates residual voltage.
  • Designed for product development and laboratory use.
  • High efficiency design, low power consumption.
  • All test leads included.
  • Calibrated to NIST standards.
  • HTT-1 and HTT-1RHipot and Ground Continuity Function Checker Compatible
Product tags