Close
You have no items in your shopping cart.

Com-Power LI-3P-132 Three-Phase LISN

Manufacturer part number: LI-3P-132
150kHz to 30MHz
PURCHASE
AvailableQTYPrice
New:   1
+ -
$5,195.00
Used:   1
+ -
$0.00Configurations
X

Available Configurations

THREE PHASE LISN, 150 KHZ - 30 MHZ, 32 AMPS
30016825
$0

Key Features and Functions

The Com-Power LI-3P-132 LISN provides the necessary measurement platform for performing power line conducted emissions compliance testing as required by most worldwide standards for commercial products. The LISN will perform each of the following functions during the measurement:
  • provide a defined, stable impedance across the measurement frequency range;
  • isolate the EUT and measurement circuit from the power source, thereby minimizing its influence on the measurements; and,
  • couple the disturbance voltages to the coaxial measurement port, which connects to the measuring instrument.

The LI-3P-132 LISN uses air-core inductors to prevent saturation and permeability variation. The mounting plates are left unpainted in order to facilitate connection to earth ground in their installation, which is essential due to high leakage currents. The side panels for the LISN are louvered for cooling purposes.

The LI-3P-1x series consists of four separate models of four-conductor, 50Ω / 50 μH Line Impedance Stabilization Networks (LISNs). The primary differences between the four models are their respective current ratings:
  • LI-3P-116 16 Amps (per line, continuous)
  • LI-3P-132 32 Amps (per line, continuous)
  • LI-3P-163 63 Amps (per line, continuous)
  • LI-3P-1100 100 Amps (per line, continuous)
  • Mating Socket Connector for Power Input Cable
  • Mating Plug Connector for EUT Power Cable
  • RLI-100 Remote LISN Interface
  • Fiber Optic Cable (30 meters)
  • AC Power Adapters (6 VDC, 500 mA, unregulated)
Voltage Rating500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V
Frequency Range150 kHz to 30 MHz
Standards MetANSI C63.4, CISPR 16-1-2
RF ConnectorRF Measurement Port 50Ω - N-Type (female)
Inductors50 µH
Mains & EUT ConnectionsRemote Interface Power Input Port 5.5/2.5 mm Power Jack
Current Rating32 Amperes
Insertion lossless than 0.7 dB
Application/Test TypePower Line Conducted Emissions Tests
Isolationmore than 40 dB
Dimensions19.3” x 13.9” x 2.3"
Weight27.5 lbs.
Description

Key Features and Functions

The Com-Power LI-3P-132 LISN provides the necessary measurement platform for performing power line conducted emissions compliance testing as required by most worldwide standards for commercial products. The LISN will perform each of the following functions during the measurement:
  • provide a defined, stable impedance across the measurement frequency range;
  • isolate the EUT and measurement circuit from the power source, thereby minimizing its influence on the measurements; and,
  • couple the disturbance voltages to the coaxial measurement port, which connects to the measuring instrument.

The LI-3P-132 LISN uses air-core inductors to prevent saturation and permeability variation. The mounting plates are left unpainted in order to facilitate connection to earth ground in their installation, which is essential due to high leakage currents. The side panels for the LISN are louvered for cooling purposes.

The LI-3P-1x series consists of four separate models of four-conductor, 50Ω / 50 μH Line Impedance Stabilization Networks (LISNs). The primary differences between the four models are their respective current ratings:
  • LI-3P-116 16 Amps (per line, continuous)
  • LI-3P-132 32 Amps (per line, continuous)
  • LI-3P-163 63 Amps (per line, continuous)
  • LI-3P-1100 100 Amps (per line, continuous)