Key Features and Functions

The Com-Power CDN-M225E is designed for testing products that uses two conductor power cable. It has two 4 mm shrouded banana socket for both EUT and AE power connections. The CDN-M225E can handle up to 25 Amps AC and 17 Amps DC of current. The RF disturbance signal coupling port is female BNC. It can handle up to 40V of RF input Voltage. The bottom surface of the CDN is not painted for easy and effective grounding.

All Com-Power CDNs are individually calibrated. The Com-Power CDN-M225E fully complies with the requirement contained in the IEC 61000-4-6 and CISPR 16-1-2. All Com-Power CDNs can be purchased separately or as part of the CIS series conducted immunity test system. This is a pre-packaged solution that includes an ACS series power amplifier and all accessories required for the test.

  • 150 MHz - 230 MHz Frequency Range
  • Designed for IEC / EN 61000-4-6
  • Two conductor power cable
Voltage Rating250 V AC / 350 V DC (Line to Ground)
Frequency Range150 kHz to 230 MHz
RF Connector50 Ω BNC (Female)
Standards MetIEC / EN 61000-4-6
Mains & EUT Connections4 mm shrouded banana sockets
Common Mode Impedance150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60Ω
Current Rating25 Amps AC / 17 Amps DC (Max)
Application/Test Typetwo conductor power cable
RF Input Voltage40 V (Max)
Voltage Division Factor9.5 dB +4 / -1
Decoupling of Common Mode Disturbance≥ 40dB (EUT/AE)
Dimensions6 x 6 x 13 inches 15.2 x 15.2 x 33 cm
Weight5 lbs. 2.3 kg
Description

Key Features and Functions

The Com-Power CDN-M225E is designed for testing products that uses two conductor power cable. It has two 4 mm shrouded banana socket for both EUT and AE power connections. The CDN-M225E can handle up to 25 Amps AC and 17 Amps DC of current. The RF disturbance signal coupling port is female BNC. It can handle up to 40V of RF input Voltage. The bottom surface of the CDN is not painted for easy and effective grounding.

All Com-Power CDNs are individually calibrated. The Com-Power CDN-M225E fully complies with the requirement contained in the IEC 61000-4-6 and CISPR 16-1-2. All Com-Power CDNs can be purchased separately or as part of the CIS series conducted immunity test system. This is a pre-packaged solution that includes an ACS series power amplifier and all accessories required for the test.

  • 150 MHz - 230 MHz Frequency Range
  • Designed for IEC / EN 61000-4-6
  • Two conductor power cable