High performance, enhanced range with full 1 x 64 PON support, up to 42dB.

The MT9083 delivers full featured OTDR performance plus loss test set and quality of service measurement in a surprisingly small and lightweight package. At only 28.4cm wide x 20cm tall x 7.7cm deep and 2.6kg (5.7lbs), it is field portable, yet rugged enough to withstand the outside plant environment. When equipped with power meter and visual light source options, it replaces several, larger pieces of test equipment.

PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

Anritsu OTDR ACCESS Master MT9083B2

MT9083B2: High performance, enhanced range with full 1 x 64 PON support, up to 42dB.

The ACCESS Master MT9083B2 features a 7-inch widescreen TFT-LCD display for use both indoors and outdoors, enhanced battery operation time (up to 12 hours) increased operating temperature range (-10° to 50°C), and short-cut function keys.

Until now, installing and maintaining optical networks required technicians to carry a variety of equipment which was not only cumbersome, but also expensive. Hearing this common complaint, Anritsu engineers have developed their new line of the ACCESS Master MT9083. These test sets are designed to make your measurement experience simple and error-free with true one-button fault location, pass/fail classification, automated file saving and naming, and even a macrobend detection feature for identifying installation issues. They feature multiple wavelengths and options to satisfy any network testing requirement: access or metro, FTTx, or LAN - all without straining your budget.

For customers installing and maintaining metro area or core networks, the MT9082B2 offers an automated fiber construction application and multiple wavelengths including specialty applications.

Additional features include an integrated light source and power meter plus options to customize the unit including higher range power meters, visual fault locator (VFL), and connector inspection microscope to ensure complete network evaluation with a single tool.

Protector Option

  • MT9083B2-010: Protector option (includes rubber side-bumpers, display cover, and shoulder strap)

Optical Configurations

  • MT9083B2-053: 1310/1550nm, SM; general-purpose model for construction, maintenance, and fault location
  • MT9083B2-055: 1310/1550nm & 1650nm, SM; general-purpose model for construction, maintenance, and fault location plus In-service measurement - integrated filter to block transmissions
  • MT9083B2-056: 1310/1490/1550nm, SM; general-purpose plus 1490nm for FTTx/PON applications
  • MT9083B2-057: 1310/1550/1625nm, SM; general-purpose plus enhanced macrobend detection at 1625nm
  • MT9083B2-058: 1310/1490/1550/1625nm, SM; full spectrum characterization for CWDM applications
  • MT9083B2-063: 850/1300nm MM, 1310/1550nm SM; best unit for installation/maintenance of hybrid networks

Loss Test Set Options; Optical Power Meter options must be added as separate, chargeable line items

  • MT9083B2-004: SMF Optical Power Meter (UPC only)
  • MT9083B2-005: SMF High Power Optical Power Meter (UPC/APC)
  • MT9083B2-007: SMF/MMF Optical Power Meter (UPC/APC)
  • MT9083B2-002: Laser Diode Visible Light Source

The ACCESS Master MT9083 can be optioned to feature up to three optical ports: single mode OTDR, multimode OTDR, and an Optical Power Meter (options -004, -005, and -007). Selecting a single connector code below will populate all optical ports with that connector type or customer can select different adapters by specifying the adapter for each of the three optical ports.

Connector Types

  • MT9083B2-025 FC-APC Connector; single mode OTDR only (additional charge applies)
  • MT9083B2-026 SC-APC Connector; single mode OTDR only (additional charge applies)
  • MT9083B2-037 FC Connector
  • MT9083B2-038 ST Connector
  • MT9083B2-039 DIN Connector
  • MT9083B2-040 SC Connector

Baseline Features

  • Ready to test in
  • Test all day without recharging
  • Specialized testing modes simplify operation
  • High resolution and high dynamic range ensure thorough and complete fiber evaluation
  • Intelligent analysis software identifies problem splices, connectors, and even macrobends
  • Rugged, sealed design provides years of service in the most challenging environments
  • Test up to four wavelengths with a single unit; single mode, multimode, or both
  • ITU-T recommended 1650nm for in-service troubleshooting
  • Verify connector quality with optional connector inspection microscope
  • SCPI remote command support
  • Feature offering easy graphical summary & PDF reporting
  • Password protection feature for important file on-internal memory

Enhancements

  • Large, 7-inch, high resolution 800 x 400 display with LED backlight
  • Battery operation time: Up to 12 hours
  • Wide operating temperature range: -10°C to 50°C
  • Light weight: only 2.6kg (5.7lbs)
  • New Fiber Visualizer feature offering easy graphical summary & PDF reporting
  • Password protection feature to foil theft
  • Automated connector PASS/FAIL based on IEC 61300-3-35
  • Calibration & certificate
  • Manual
  • Battery pack
  • AC adaptor
  • All standard accessories
Description

Anritsu OTDR ACCESS Master MT9083B2

MT9083B2: High performance, enhanced range with full 1 x 64 PON support, up to 42dB.

The ACCESS Master MT9083B2 features a 7-inch widescreen TFT-LCD display for use both indoors and outdoors, enhanced battery operation time (up to 12 hours) increased operating temperature range (-10° to 50°C), and short-cut function keys.

Until now, installing and maintaining optical networks required technicians to carry a variety of equipment which was not only cumbersome, but also expensive. Hearing this common complaint, Anritsu engineers have developed their new line of the ACCESS Master MT9083. These test sets are designed to make your measurement experience simple and error-free with true one-button fault location, pass/fail classification, automated file saving and naming, and even a macrobend detection feature for identifying installation issues. They feature multiple wavelengths and options to satisfy any network testing requirement: access or metro, FTTx, or LAN - all without straining your budget.

For customers installing and maintaining metro area or core networks, the MT9082B2 offers an automated fiber construction application and multiple wavelengths including specialty applications.

Additional features include an integrated light source and power meter plus options to customize the unit including higher range power meters, visual fault locator (VFL), and connector inspection microscope to ensure complete network evaluation with a single tool.

Protector Option

  • MT9083B2-010: Protector option (includes rubber side-bumpers, display cover, and shoulder strap)

Optical Configurations

  • MT9083B2-053: 1310/1550nm, SM; general-purpose model for construction, maintenance, and fault location
  • MT9083B2-055: 1310/1550nm & 1650nm, SM; general-purpose model for construction, maintenance, and fault location plus In-service measurement - integrated filter to block transmissions
  • MT9083B2-056: 1310/1490/1550nm, SM; general-purpose plus 1490nm for FTTx/PON applications
  • MT9083B2-057: 1310/1550/1625nm, SM; general-purpose plus enhanced macrobend detection at 1625nm
  • MT9083B2-058: 1310/1490/1550/1625nm, SM; full spectrum characterization for CWDM applications
  • MT9083B2-063: 850/1300nm MM, 1310/1550nm SM; best unit for installation/maintenance of hybrid networks

Loss Test Set Options; Optical Power Meter options must be added as separate, chargeable line items

  • MT9083B2-004: SMF Optical Power Meter (UPC only)
  • MT9083B2-005: SMF High Power Optical Power Meter (UPC/APC)
  • MT9083B2-007: SMF/MMF Optical Power Meter (UPC/APC)
  • MT9083B2-002: Laser Diode Visible Light Source

The ACCESS Master MT9083 can be optioned to feature up to three optical ports: single mode OTDR, multimode OTDR, and an Optical Power Meter (options -004, -005, and -007). Selecting a single connector code below will populate all optical ports with that connector type or customer can select different adapters by specifying the adapter for each of the three optical ports.

Connector Types

  • MT9083B2-025 FC-APC Connector; single mode OTDR only (additional charge applies)
  • MT9083B2-026 SC-APC Connector; single mode OTDR only (additional charge applies)
  • MT9083B2-037 FC Connector
  • MT9083B2-038 ST Connector
  • MT9083B2-039 DIN Connector
  • MT9083B2-040 SC Connector
Product tags