Measurements
- PIM vs. Time: 3rd, 5th, and 7th order intermodulation product when in receive band (user selectable)
- Distance-to-PIM: Distance and relative magnitude of multiple PIM sources
- Swept PIM: 3rd, 5th, and 7th order intermodulation product when in receive band (user selectable)
- Noise Floor: Noise Floor vs. Time at selected IM product frequency
Instrument Setup Parameters
- Frequency: Carrier F1, Carrier F2, Intermodulation Order (3rd, 5th, 7th)
- Amplitude: Ref Value, Scale, Auto Range (On/Off), Amplitude Tone (On/Off)
- Setup: Output Power, Test Duration (1s to 1,200s)
- Limit Lines: Limit (Upper/Lower), On/Off, Limit Move, Limit Alarm (On/Off, PASS/FAIL indicator)
- GPS: On/Off, 3.3/5.0V
- DTP: Cable Velocity, Distance
PCS/AWS
- Tx1: 1930MHz to 1940MHz
- Tx2: 1955MHz to 1995MHz
- Tx3: 2110MHz to 2155MHz
- Rx1: 1850MHz to 1910MHz (using Tx1 and Tx2)
- Rx2: 1710MHz to 1755MHz (using Tx1 and Tx3)
PIM Master Connectors
- Test Port: 7/16 DIN, female, 50Ω
- Dual USB Type-A: 2x Type A (connect USB Flash Drive and USB Power Sensor)
- USB Mini-B: 1x Mini-B (connect to PC for data transfer)
- GPS: SMA, female (with GPS option only)
- External Power: 2.1 mm x 5.5 mm barrel connector, 12 to 15VDC, <5.0A
Display
- Size: 213mm (8.4in) touch screen
- Resolution: 800 x 600
Electromagnetic Compatibility
- Australia and New Zealand: C-tick N274
- Interference: EN 61326-1:2006
- Emissions: EN 55011:2007
- Immunity: EN 61000-4-2/-3/-4-4/-4-5/-4-6/-4-11
- European Union: CE Mark, EMC Directive 2004/108/EC
Dimensions
- Size: 350mm x 314mm x 152mm
- Weight: 9.0kg to 12.2kg (20lb to 27lb)