Close
You have no items in your shopping cart.

Amplifier Research FM7004AM1 Field Monitor

Manufacturer part number: FM7004AM1
$0.00
excluding shipping
0.4 - 1000V/m, 12.0mA/m - 17A/m
+ -
X

Available Configurations

FIELD MONITOR, 0.4 - 1000V/M, 12.0MA/M - 17A/M, M1
30018146
$0

The Amplifier Research FM7004A is a versatile electric and magnetic field monitoring system which performs all measurement display and control functions for field related testing. The FM7004A accepts inputs from up to 4 isotropic Field Probes which are all sold separately to match the test application.

The FM7004A field monitor provides four digital interfaces (IEEE-488, USB, RS-232, and Ethernet) and a highly readable, user configurable, LCD touch tisplay. The monitor is menu driven and can be controlled from the front panel or remotely through any of the interfaces. The FM7004A displays up to four probe readings simultaneously, in any combination of the "E" field or "H" field 7000 series probes. Readings from each axis, plus the composite reading, are displayed simultaneously. The FM7004A recognizes each attached 7000 series probe (FL, PL, FA, FP, FH) and automatically displays the proper decimal places and units.

The FM7004A has the ability to correct probe readings over frequency using a set of correction factors stored in its internal memory. The FM7004A allows for up to six tables of field probe correction factors to be stored. Each table of correction factors can contain up to 30 different frequency points. The tables are loaded on the FM7004A using the USB port and the Table Loader program.

  • Sensitivity: 0.4 - 1400 V/m (probe dependent); 12.0 mA/m-17 (probe dependent)
  • Frequency Response: 5 kHz - 60 GHz (probe dependent)
  • Inputs: Up to 4 independent probes, through 4 F/O FSMA pairs
  • Overload Withstand: Probe-dependent
  • Output: Graphical, color LCD touch display; IEEE-488 (GPIB); USB 2.0 (test and measurement class); RS-232; Ethernet
  • Sample Rate: Probe dependent
  • Input Voltage: Universal input 90 - 260 VAC, 50 - 60 Hz
  • Input Current: 0.2 - 0.6 Amps
  • Input Type: IEC Inlet with filter
  • Fuse: 1A, 5 x 20 mm slow blow
  • Correction Factor Tables: Stores up to 6 different tables; 2 to 30 frequency points per table
  • Enclosure: Desktop case, 2U high
  • Operating Temperature Range: 10° - 40° C (50° - 104° F) @ 5 - 95% RH non-condensing
  • Size: 48.3 x 9.0 x 25.4 cm (9 x 3.5 x 10 in) without enclosure; 49.8 x 12.7 x 30.5 cm (19.6 x 5.0 x 12.0 in) with enclosure
  • Weight: 2.3 kg (5 lb) without enclosure; 6.7 kg (14.75 lb) with enclosure
Description

The Amplifier Research FM7004A is a versatile electric and magnetic field monitoring system which performs all measurement display and control functions for field related testing. The FM7004A accepts inputs from up to 4 isotropic Field Probes which are all sold separately to match the test application.

The FM7004A field monitor provides four digital interfaces (IEEE-488, USB, RS-232, and Ethernet) and a highly readable, user configurable, LCD touch tisplay. The monitor is menu driven and can be controlled from the front panel or remotely through any of the interfaces. The FM7004A displays up to four probe readings simultaneously, in any combination of the "E" field or "H" field 7000 series probes. Readings from each axis, plus the composite reading, are displayed simultaneously. The FM7004A recognizes each attached 7000 series probe (FL, PL, FA, FP, FH) and automatically displays the proper decimal places and units.

The FM7004A has the ability to correct probe readings over frequency using a set of correction factors stored in its internal memory. The FM7004A allows for up to six tables of field probe correction factors to be stored. Each table of correction factors can contain up to 30 different frequency points. The tables are loaded on the FM7004A using the USB port and the Table Loader program.