PERFORMANCE
Testing was done at 100 Hz. Continuous DC power levels are lower. See DC Specifications chart for test conditions.
Frequency Response, DC - 300 kHz (1 watt): +1.0 to -1.5 dB
8-Ohm Power Response (continuous duty):
DC to 60 kHz: ± 140 Vpk
DC to 200 kHz: ± 65 Vpk
DC to 350 kHz: ± 45 Vpk
Slew Rate: 75 V/µSec
Residual Noise:
10 Hz to 300 kHz: 950 µV (0.95 mV)
10 Hz to 80 kHz: 300 µV (0.3 mV)
Signal-to-Noise Ratio:
10 Hz - 30 kHz: –113 dB
10 Hz - 80 kHz: –106.6 dB
10 Hz - 500 kHz: –99.9 dB
Unit to Unit Phase Error: ±0.1 degrees at 60 Hz
THD (DC - 30 kHz): less than 0.1%
DC Offset: Less than ±5 mV
DC Drift: Less than ±1.5mV
Output Impedance: 5.3 mOhm in Series with 0.95 µH
Phase Response (10 Hz - 10 kHz) : ±5 degrees plus 600 nsec propagation delay
INPUT CHARACTERISTICS
Balanced with ground: Three terminal barrier block connector, 20k ohm differential
Unbalanced: BNC connector, 10k ohm single ended.
Gain, Voltage Mode: 20 volts/volt; Current Mode: 5 amperes/volt
Gain Linearity (over input signal, from 0.2V to 5V): 0.15%
Max Input Voltage: ±10V, balanced or unbalanced
Common Mode Rejection: -58 dB with 5V input
STATUS DISPLAY, CONTROL, I/O
Front Panel LED Displays indicate: Ready, Standby, Fault, Over Temp, Over Voltage, Overload
Soft Touch Switches for: Run, Stop, Reset
Gain Control, when enabled: Voltage gain adjustable from 20 to 0
On/Off Breaker
Back Panel Power Connection: 25 Amp IEC (with retention latch)
Signal Output: Three-position terminal strip (OUTPUT/COM/CHASSIS GROUND)
Signal Input: User Selectable BNC or Barrier Strip, Balanced or Unbalanced
COMMUNICATION CAPABILITIES
Current Monitor: 5A/V ± 1%; 2.5A/V ± 1% (differential configuration)
Reporting: System Fault, Over Temp, Over Voltage, Over Load
Remote Control via Interlock Connector: Blanking control, Force to Standby, Reset after a fault
PROTECTION
Over/Under Voltage:
± 10% from specified supply voltage amplifier is forced to Standby
Over Current:
Breaker protection on both main power and low voltage supplies
Over Temperature:
Separate Output transistor, heat sink, and transformer temperature monitoring and protection
PHYSICAL CHARACTERISTICS
Chassis:
The Amplifier is designed for stand- alone or rack-mounted operation. The Chassis is black aluminum with a powder coat finish. The unit occupies two EIA 19-inch-wide units.
Weight: 41 lbs (18.6 kg), Shipping 51 lbs (23.2 kg)
AC Power: Single phase, 120 VAC, 60 Hz, 20 Amp service; (220-240 VAC, 50-60 Hz, 10 Amp service model available)
Operating Temperature:
10°C to 50°C (50°F to 122°F), maximum output Power de-rated above 30°C (86°F).
Humidity: 70% or less, non-condensing
Cooling: Forced air cooling from front to back through removable filters.
Airflow: 180CFM
Dimensions: 19” x 22.75” x 3.5” (48.3 cm x 57.8 cm x 8.9 cm)