Fluke 5520A Calibrator

Manufacturer part number: 5520A-525A/LEADS
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

The 5520A Multi-Product Calibrator sources direct voltage and current, alternating voltage and current with multiple waveforms and harmonics, two simultaneous voltage outputs or voltage, and current to simulate dc and ac power with phase control, resistance, capacitance, thermocouples, and RTDs. The 5520A can also measure thermocouple temperature, humidity (with probe), and pressure using one of 28 Fluke Calibration 700 Series pressure modules. Three options add the capability to calibrate oscilloscopes up to 1.1 GHz. And the 5520A-PQ Power Quality Option enables the 5520A to calibrate power quality instrumentation to the standards of the IEC and other regulatory agencies.

Features:

  • Handheld and bench meters (analog and digital) up to 6 1/2 digits
  • Thermocouple and RTD thermometers
  • Process calibrators
  • Data loggers
  • Strip and chart recorders
  • Watt meters
  • Power harmonics analyzers
  • Current clamps and clamp meters
  • Analog or digital handheld and bench oscilloscopes (with options)
  • Panel meters
  • Graphical multimeters
  • Power meters, disturbance analyzers, power quality monitors, recorders and other power quality-related equipment (with option)
  • Voltage DC Range: 0 to ±1020V
  • Current DC Range: 0 to ±20.5A
  • Resistance Range: 0 to 1100 MΩ
  • Voltage AC Range: 1 mV to 1020V, 10 Hz to 500 kHz, Sine
  • Current AC Range: 29 mA to 20.5A 10 Hz to 30 kHz, Sine
  • Capacitance Range: 0.19 nF to 110 mF
  • Thermocouple Source and Measure Range: -250°C to +2316°C (11 types)
  • RTD Source Range: -200°C to +630°C (8 types)
  • DC Power Range: 10.9 mW to 20.5 kW
  • AC Power: 10.9 mW to 20.5 kW, 45-65 Hz, PF=1
  • Phase Range: 0 to ± 179.99°, 10 Hz to 30 kHz
  • Frequency Range: 0.01 Hz to 2.0 MHz
  • METROLOGY SOFTWARE, REQUIRES MET/CAL-L
  • MET BASE 7 SOFTWARE
  • ML CD:ops/prog/guides (COPY MASTERCOPY)
  • CD CRYSTAL REPORTS 5520A (FLU)
  • ML METROLOGY INSTALL GU 5520A (FLU)
  • ML METROLOGY USERS ML 5520A (FLU)
  • ML GETTING STARTED MET 5520A (FLU)
  • LICENSE,MET-CAL-L,SGL USER;5500A (FLU)
  • DISK USER LICENSE MET CAL (FLU)
  • ML QUICK REF CARD 5520A (FLU)
  • CD MET/BASE-6 5520A (FLU)
  • CD MET/BASE UTILITY 5520A (FLU)
  • CD CALIBRATION PROCEDURES 5520A (FLU)
  • ML INSTRSHEET MET REMOTE 5520A (FLU)
  • POWER CORD (7'6" BLK)AMER; (NEWARK)
Description

The 5520A Multi-Product Calibrator sources direct voltage and current, alternating voltage and current with multiple waveforms and harmonics, two simultaneous voltage outputs or voltage, and current to simulate dc and ac power with phase control, resistance, capacitance, thermocouples, and RTDs. The 5520A can also measure thermocouple temperature, humidity (with probe), and pressure using one of 28 Fluke Calibration 700 Series pressure modules. Three options add the capability to calibrate oscilloscopes up to 1.1 GHz. And the 5520A-PQ Power Quality Option enables the 5520A to calibrate power quality instrumentation to the standards of the IEC and other regulatory agencies.

Features:

  • Handheld and bench meters (analog and digital) up to 6 1/2 digits
  • Thermocouple and RTD thermometers
  • Process calibrators
  • Data loggers
  • Strip and chart recorders
  • Watt meters
  • Power harmonics analyzers
  • Current clamps and clamp meters
  • Analog or digital handheld and bench oscilloscopes (with options)
  • Panel meters
  • Graphical multimeters
  • Power meters, disturbance analyzers, power quality monitors, recorders and other power quality-related equipment (with option)