Close
You have no items in your shopping cart.

Keysight 11941A Close Field Probe

Manufacturer part number: 11941A
9 kHz -30 MHz
PURCHASE
Available QTY Price
New:   0
+ -
$0.00
Used:   2
+ -
$420.00 Configurations
X

Available Configurations

CLOSE FIELD PROBE, 9 KHZ TO 30 MHZ
30004865
$420
CLOSE FIELD PROBE, 9 KHZ TO 30 MHZ
30007947
$420

The Keysight (Agilent/HP) 11941A is a hand-held close field probe specially designed to measure magnetic field radiation from surface currents, slots, cable, and ICs for EMC diagnostic and troubleshooting measurements between 9 kHz and 30 MHz. Its unique design results in a high level of electric field rejection. This significantly reduces errors allowing calibrated and repeatable measurements. Each probe is calibrated and comes with a two-meter, RG-223 coaxial cable, an SMA (f) to Type-N (m) adapter, and an SMA (f) to BNC (m) adapter.

Features:

  • High level of electric field rejection
  • Allows calibrated and repeatable measurements
  • Maximum Input Power: 0.5 watts
  • Temperature Range: Variation over 0 °C to +40 °C
  • Dielectric Breakdown: ±1 kV, typical
  • Connector Type: SMA, replaceable barrel
  • VSWR: < 3:1
  • Antenna Factor Accuracy: Individually calibrated to within ±2 dB in a 377 ohm field impedance
  • Antenna Factor: Measured for each unit at 0.009, 0.100, 1, 10 and 30 MHz to within ±2 dB in a 377 ohm field impedance
  • Temperature Range
    • Operating: 0°C to +40°C <± dB
    • Storage: -10°C to + 65°C
  • Frequency Range: 9 kHz 0 30 MHz
  • Connector: SMA, replaceable barrel
  • Maximum Input Power: 0.5 watts
  • Maximum Voltage at Top: 1kV (dc + peak ac)
  • Weight
    • Net: 0.10 kg (0.22 lbs)
    • Shipping: 0.56 kg (1.2 lbs)
  • Manual
  • Adpater, N(m) to SMA(f)
  • Adapter, BNC(m) to SMA(f)
  • Cable, M-M SMA
Description

The Keysight (Agilent/HP) 11941A is a hand-held close field probe specially designed to measure magnetic field radiation from surface currents, slots, cable, and ICs for EMC diagnostic and troubleshooting measurements between 9 kHz and 30 MHz. Its unique design results in a high level of electric field rejection. This significantly reduces errors allowing calibrated and repeatable measurements. Each probe is calibrated and comes with a two-meter, RG-223 coaxial cable, an SMA (f) to Type-N (m) adapter, and an SMA (f) to BNC (m) adapter.

Features:

  • High level of electric field rejection
  • Allows calibrated and repeatable measurements
  • Maximum Input Power: 0.5 watts
  • Temperature Range: Variation over 0 °C to +40 °C
  • Dielectric Breakdown: ±1 kV, typical
  • Connector Type: SMA, replaceable barrel
  • VSWR: < 3:1
  • Antenna Factor Accuracy: Individually calibrated to within ±2 dB in a 377 ohm field impedance